This Part 15 of the HD details the specifications for multicore cables of rated voltage 300/500 V, insulated and sheathed with heat resistance silicone rubber, with or without strain-bearing element. The maximum permissible conductor temperature is 180 °C. Each cable shall comply with the appropriate requirements given in Part 1 of this HD and the particular requirements of this part. NOTE The overall dimensions of the cables of this part of HD 22 have been calculated in accordance with EN 60719.
Registration number (WIID)
51595
Scope
This Part 15 of the HD details the specifications for multicore cables of rated voltage 300/500 V, insulated and sheathed with heat resistance silicone rubber, with or without strain-bearing element. The maximum permissible conductor temperature is 180 °C. Each cable shall comply with the appropriate requirements given in Part 1 of this HD and the particular requirements of this part. NOTE The overall dimensions of the cables of this part of HD 22 have been calculated in accordance with EN 60719.