This European standard specifies a method for determining the consistence of fresh concrete by the
slump test.
The slump test is sensitive to changes in the consistence of concrete, which correspond to slumps
between 10 mm and 210 mm. Beyond these extremes the measurement of slump can be unsuitable and
other methods of determining the consistency should be considered.
If the slump continues to change over a period of 1 min after withdrawing of the cone, the slump test is
not suitable as a measure of consistence.
The test is not suitable when the declared value of D of the coarsest fraction of aggregates actually used
in the concrete (Dmax) is greater than 40 mm.
Registration number (WIID)
64380
Scope
This European standard specifies a method for determining the consistence of fresh concrete by the
slump test.
The slump test is sensitive to changes in the consistence of concrete, which correspond to slumps
between 10 mm and 210 mm. Beyond these extremes the measurement of slump can be unsuitable and
other methods of determining the consistency should be considered.
If the slump continues to change over a period of 1 min after withdrawing of the cone, the slump test is
not suitable as a measure of consistence.
The test is not suitable when the declared value of D of the coarsest fraction of aggregates actually used
in the concrete (Dmax) is greater than 40 mm.