This Technical Report provides details of filtration systems used for applications ranging from a single house up to and included 50 PT. The filtration systems receive domestic wastewater from septic tanks manufactured according to the requirements given in EN 12566-1 and EN 12566-4.
This document is a code of practice and gives design parameters, construction details, installation and component requirements for constructed sand filters and subsurface flow sand or gravel reed beds.
Registration number (WIID)
7294
Scope
This Technical Report provides details of filtration systems used for applications ranging from a single house up to and included 50 PT. The filtration systems receive domestic wastewater from septic tanks manufactured according to the requirements given in EN 12566-1 and EN 12566-4.
This document is a code of practice and gives design parameters, construction details, installation and component requirements for constructed sand filters and subsurface flow sand or gravel reed beds.