Project No.prCEN/TS 18406
TitleShall be according to EN 416:2019, Clause 1 [Scope] with the following addition to be inserted after paragraph 1 of the text: This document covers radiant tube heaters and tube heater systems that are intended to be connected to gas grids including gas grids for natural gases of the 2nd gas family where up to 20 mol-% H2 is added to natural gas (H2NG-Y20) and where the quality of the distributed gas without adding the hydrogen is not likely to vary to a large extend over the lifetime of the appliance. This document covers also radiant tube heaters and tube heater systems that are intended to be connected to hydrogen gas grids where the quality of the distributed hydrogen gas (4th gas family at nominal pressure of 20 mbar) is likely expected to contain ≤ 98% hydrogen and stay within a Wobbe range of 42 – 46 MJ/m
Registration number (WIID)84129
ScopeShall be according to EN 416:2019, Clause 1 [Scope] with the following addition to be inserted after paragraph 1 of the text: This document covers radiant tube heaters and tube heater systems that are intended to be connected to gas grids including gas grids for natural gases of the 2nd gas family where up to 20 mol-% H2 is added to natural gas (H2NG-Y20) and where the quality of the distributed gas without adding the hydrogen is not likely to vary to a large extend over the lifetime of the appliance. This document covers also radiant tube heaters and tube heater systems that are intended to be connected to hydrogen gas grids where the quality of the distributed hydrogen gas (4th gas family at nominal pressure of 20 mbar) is likely expected to contain ≤ 98% hydrogen and stay within a Wobbe range of 42 – 46 MJ/m
StatusIzstrādē
ICS groupNot set