This European Standard describes the determination of decoquinate This high-performance liquid chromatographic (HPLC) method with a fluorescence detection is applicable to the quantification of decoquinate content in complete , complementary compound feeds, supplements , premixture and feed additives. The limit of detection is around 0.1 mg/kg and the limit of quantification is around 0.5 mg/kg
Registration number (WIID)
28298
Scope
This European Standard describes the determination of decoquinate This high-performance liquid chromatographic (HPLC) method with a fluorescence detection is applicable to the quantification of decoquinate content in complete , complementary compound feeds, supplements , premixture and feed additives. The limit of detection is around 0.1 mg/kg and the limit of quantification is around 0.5 mg/kg