<p class="MsoBodyText"><span lang="EN-GB">This document specifies requirements for compressed air foam systems (CAFS) in which foam concentrate and compressed air are continuously added to the water being discharged from the fire-fighting pump. This document is applicable to CAFS that can be permanently installed in fire-fighting vehicles, or that are transportable or mobile.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document specifies requirements for CAFS which are used at ambient temperatures ranging from –10 °C to +40 °C.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document does not apply to stationary CAFS.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document does not apply to requirements for hazards related to handling foam concentrates, noise generated by CAFS, drives, auxiliary equipment, power sources, or pumps connected to the CAFS.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document does not specify requirements for special hazards arising from particular conditions under which CAFS are used, for example:</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">immunity against electromagnetic fields and electrostatic discharge;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">operation without supervision;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">events specific to the location where the CAFS is set up (e.g. on public roads);</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">handling of any equipment, devices, etc. which have to be connected to the CAFS or are joined to it (e.g. branch pipes, nozzles and pressure hoses);</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">decommissioning and disposal.</span></p>
Registration number (WIID)
87687
Scope
<p class="MsoBodyText"><span lang="EN-GB">This document specifies requirements for compressed air foam systems (CAFS) in which foam concentrate and compressed air are continuously added to the water being discharged from the fire-fighting pump. This document is applicable to CAFS that can be permanently installed in fire-fighting vehicles, or that are transportable or mobile.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document specifies requirements for CAFS which are used at ambient temperatures ranging from –10 °C to +40 °C.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document does not apply to stationary CAFS.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document does not apply to requirements for hazards related to handling foam concentrates, noise generated by CAFS, drives, auxiliary equipment, power sources, or pumps connected to the CAFS.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document does not specify requirements for special hazards arising from particular conditions under which CAFS are used, for example:</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">immunity against electromagnetic fields and electrostatic discharge;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">operation without supervision;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">events specific to the location where the CAFS is set up (e.g. on public roads);</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">handling of any equipment, devices, etc. which have to be connected to the CAFS or are joined to it (e.g. branch pipes, nozzles and pressure hoses);</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">decommissioning and disposal.</span></p>