Project No.ISO 4259-5:2023
Title<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho';">This document specifies statistical methodology for assessing the expected agreement between two test methods that purport to measure the same property of a material, and for deciding if a simple linear bias correction can further improve the expected agreement.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho';">This document is applicable for analytical methods which measure quantitative properties of petroleum or petroleum products resulting from a multi-sample-multi-lab study (MSMLS). These types of studies include but are not limited to interlaboratory studies (ILS) meeting the requirements of </span><span class="stdpublisher"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; color: black; mso-color-alt: windowtext;">ISO </span></span><span class="stddocNumber"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho'; color: black; mso-color-alt: windowtext;">4259</span></span><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho';">-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span> or equivalent, and proficiency testing programmes (PTP) meeting the requirements of <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO </span></span><span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">4259</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">3</span></span> or equivalent. </span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho';">The methodology specified in this document establishes the limiting value for the difference between two results where each result is obtained by a different operator using different apparatus and two methods X and Y, respectively, on identical material. One of the methods (X or Y) has been appropriately bias-corrected to agree with the other in accordance with this practice. This limit is designated as the between-methods reproducibility. This value is expected to be exceeded with a probability of 5 % under the correct and normal operation of both test methods due to random variation.</span></p> <p class="Note" style="tab-stops: 19.85pt 39.7pt 48.25pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho';">NOTE<span style="mso-tab-count: 1;">      </span>Further conditions for application of this methodology are given in </span><span class="citesec"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; color: black; mso-color-alt: windowtext;">5.1 and 5.2</span></span><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho';">.</span></p>
Registration number (WIID)80879
Scope<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho';">This document specifies statistical methodology for assessing the expected agreement between two test methods that purport to measure the same property of a material, and for deciding if a simple linear bias correction can further improve the expected agreement.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho';">This document is applicable for analytical methods which measure quantitative properties of petroleum or petroleum products resulting from a multi-sample-multi-lab study (MSMLS). These types of studies include but are not limited to interlaboratory studies (ILS) meeting the requirements of </span><span class="stdpublisher"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; color: black; mso-color-alt: windowtext;">ISO </span></span><span class="stddocNumber"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho'; color: black; mso-color-alt: windowtext;">4259</span></span><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho';">-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span> or equivalent, and proficiency testing programmes (PTP) meeting the requirements of <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO </span></span><span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">4259</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">3</span></span> or equivalent. </span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho';">The methodology specified in this document establishes the limiting value for the difference between two results where each result is obtained by a different operator using different apparatus and two methods X and Y, respectively, on identical material. One of the methods (X or Y) has been appropriately bias-corrected to agree with the other in accordance with this practice. This limit is designated as the between-methods reproducibility. This value is expected to be exceeded with a probability of 5 % under the correct and normal operation of both test methods due to random variation.</span></p> <p class="Note" style="tab-stops: 19.85pt 39.7pt 48.25pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho';">NOTE<span style="mso-tab-count: 1;">      </span>Further conditions for application of this methodology are given in </span><span class="citesec"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; color: black; mso-color-alt: windowtext;">5.1 and 5.2</span></span><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho';">.</span></p>
StatusStandarts spēkā
ICS group75.080