Project No.ISO/AWI 7235
Title<p>This document specifies methods for determining</p> <ul> <li>the insertion loss, in frequency bands, of ducted silencers with and without airflow,</li> <li>the sound power level, in frequency bands, of the flow noise (or regenerated sound) generated by ducted silencers,</li> <li>the total pressure loss of silencers with airflow, and</li> <li>the transmission loss, in frequency bands, of air-terminal units.</li> </ul> <p>The measurement procedures are intended for laboratory measurements at ambient temperature. Measurements on silencers <em>in situ</em> are specified in ISO 11820.</p> <p>It is to be noted that the results determined in a laboratory according to this document will not necessarily be the same as those obtained <em>in situ</em> (installation), as different sound and flow fields will yield different results. For example, the pressure loss will be lower under laboratory conditions than <em>in situ</em>, but will be comparable between different laboratories.</p> <p>This document is applicable to all types of silencer including silencers for ventilating and air-conditioning systems, air intake and exhaust of flue gases, and similar applications. Other passive air-handling devices, such as bends, air-terminal units or T-connectors, can also be tested using this International Standard.</p> <p>It is not applicable to reactive silencers used for motor vehicles.</p>
Registration number (WIID)83982
Scope<p>This document specifies methods for determining</p> <ul> <li>the insertion loss, in frequency bands, of ducted silencers with and without airflow,</li> <li>the sound power level, in frequency bands, of the flow noise (or regenerated sound) generated by ducted silencers,</li> <li>the total pressure loss of silencers with airflow, and</li> <li>the transmission loss, in frequency bands, of air-terminal units.</li> </ul> <p>The measurement procedures are intended for laboratory measurements at ambient temperature. Measurements on silencers <em>in situ</em> are specified in ISO 11820.</p> <p>It is to be noted that the results determined in a laboratory according to this document will not necessarily be the same as those obtained <em>in situ</em> (installation), as different sound and flow fields will yield different results. For example, the pressure loss will be lower under laboratory conditions than <em>in situ</em>, but will be comparable between different laboratories.</p> <p>This document is applicable to all types of silencer including silencers for ventilating and air-conditioning systems, air intake and exhaust of flue gases, and similar applications. Other passive air-handling devices, such as bends, air-terminal units or T-connectors, can also be tested using this International Standard.</p> <p>It is not applicable to reactive silencers used for motor vehicles.</p>
StatusIzstrādē
ICS groupNot set