<p class="MsoBodyText"><span lang="EN-GB">This document specifies requirements for ten classes, four grades and seven types of wire- or textile-reinforced hydraulic hoses and hose assemblies, of nominal sizes ranging from 5 to 102. Each class has a single maximum working pressure for all sizes.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">They are suitable for use with:</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">oil-based hydraulic fluids HH, HL, HM, HR and HV, as defined in ISO 6743-4, at temperatures ranging from −40 °C to +100 °C for types AS, AC, BS and BC hoses and from −40 °C to +120 °C for types CS, CC and DC hoses;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">water-based fluids HFC, HFAE, HFAS and HFB, as defined in ISO 6743-4, at temperatures ranging from −40 °C to +70 °C;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">water at temperatures ranging from 0 °C to +70 °C.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document does not specify requirements for the connection ends. It is limited to the performance of hoses and hose assemblies. The hose assembly maximum working pressure is governed by the lowest maximum working pressure of the components.</span></p>
<p class="Note"><span lang="EN-GB">NOTE<span style="mso-tab-count: 1;"> </span>It is the responsibility of the user, in consultation with the hose manufacturer, to establish the compatibility of the hose with the fluid to be used.</span></p>
Registration number (WIID)
89310
Scope
<p class="MsoBodyText"><span lang="EN-GB">This document specifies requirements for ten classes, four grades and seven types of wire- or textile-reinforced hydraulic hoses and hose assemblies, of nominal sizes ranging from 5 to 102. Each class has a single maximum working pressure for all sizes.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">They are suitable for use with:</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">oil-based hydraulic fluids HH, HL, HM, HR and HV, as defined in ISO 6743-4, at temperatures ranging from −40 °C to +100 °C for types AS, AC, BS and BC hoses and from −40 °C to +120 °C for types CS, CC and DC hoses;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">water-based fluids HFC, HFAE, HFAS and HFB, as defined in ISO 6743-4, at temperatures ranging from −40 °C to +70 °C;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">water at temperatures ranging from 0 °C to +70 °C.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document does not specify requirements for the connection ends. It is limited to the performance of hoses and hose assemblies. The hose assembly maximum working pressure is governed by the lowest maximum working pressure of the components.</span></p>
<p class="Note"><span lang="EN-GB">NOTE<span style="mso-tab-count: 1;"> </span>It is the responsibility of the user, in consultation with the hose manufacturer, to establish the compatibility of the hose with the fluid to be used.</span></p>