Project No.ISO/TR 14179-1:2001
Title<p>This part of ISO/TR 14179 utilizes an analytical heat balance model to provide a means of calculating the thermal</p> <p>transmittable power of a single- or multiple-stage gear drive lubricated with mineral oil. The calculation is based on</p> <p>standard conditions of 25 °C maximum ambient temperature and 95 °C maximum oil sump temperature in a large</p> <p>indoor space, but provides modifiers for other conditions.</p>
Registration number (WIID)34636
Scope<p>This part of ISO/TR 14179 utilizes an analytical heat balance model to provide a means of calculating the thermal</p> <p>transmittable power of a single- or multiple-stage gear drive lubricated with mineral oil. The calculation is based on</p> <p>standard conditions of 25 °C maximum ambient temperature and 95 °C maximum oil sump temperature in a large</p> <p>indoor space, but provides modifiers for other conditions.</p>
StatusStandarts spēkā
ICS group21.200