ISO/TC 61/SC 4
Project No. | ISO 9773:2024 |
---|---|
Title | <p class="p2" style="margin-left: 0cm; text-indent: 0cm; mso-list: l0 level2 lfo1;"><!-- [if !supportLists]--><span lang="NL" style="font-size: 11.0pt; font-weight: normal;">This document specifies a small-scale laboratory screening procedure for comparing the relative burning behaviour of vertically oriented thin and relatively flexible plastics specimens exposed to a low-energy-level flame ignition source.</span></p> <p class="Note"><span lang="EN-GB">NOTE These specimens cannot be tested using method B of IEC 60695-11-10:2013 since they distort or shrink away from the applied flame source without igniting.</span></p> <p class="p2" style="margin-left: 0cm; text-indent: 0cm; mso-list: l0 level2 lfo1;"><span lang="NL" style="font-size: 11.0pt; font-weight: normal;">This test method determines the afterflame and afterglow times of specimens.</span></p> <p class="p2" style="margin-left: 0cm; text-indent: 0cm; mso-list: l0 level2 lfo1;"><span lang="NL" style="font-size: 11.0pt; font-weight: normal;">The classification system described in </span><span lang="NL"><span style="font-weight: normal;">Annex A</span></span><span lang="NL" style="font-size: 11.0pt; font-weight: normal;"> is intended for quality control and the preselection of component materials for products. The classification established by this method of test is applicable only to the material used for the specimens.</span></p> <p class="Note"><span lang="EN-GB">NOTE Test results are influenced by material components, e.g. pigments, fillers, concentrations of fire retardants.</span></p> |
Registration number (WIID) | 85513 |
Scope | <p class="p2" style="margin-left: 0cm; text-indent: 0cm; mso-list: l0 level2 lfo1;"><!-- [if !supportLists]--><span lang="NL" style="font-size: 11.0pt; font-weight: normal;">This document specifies a small-scale laboratory screening procedure for comparing the relative burning behaviour of vertically oriented thin and relatively flexible plastics specimens exposed to a low-energy-level flame ignition source.</span></p> <p class="Note"><span lang="EN-GB">NOTE These specimens cannot be tested using method B of IEC 60695-11-10:2013 since they distort or shrink away from the applied flame source without igniting.</span></p> <p class="p2" style="margin-left: 0cm; text-indent: 0cm; mso-list: l0 level2 lfo1;"><span lang="NL" style="font-size: 11.0pt; font-weight: normal;">This test method determines the afterflame and afterglow times of specimens.</span></p> <p class="p2" style="margin-left: 0cm; text-indent: 0cm; mso-list: l0 level2 lfo1;"><span lang="NL" style="font-size: 11.0pt; font-weight: normal;">The classification system described in </span><span lang="NL"><span style="font-weight: normal;">Annex A</span></span><span lang="NL" style="font-size: 11.0pt; font-weight: normal;"> is intended for quality control and the preselection of component materials for products. The classification established by this method of test is applicable only to the material used for the specimens.</span></p> <p class="Note"><span lang="EN-GB">NOTE Test results are influenced by material components, e.g. pigments, fillers, concentrations of fire retardants.</span></p> |
Status | Standarts spēkā |
ICS group | 83.080.01 13.220.40 |