Project No.ISO 20045:2023
Title<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document describes a test method to determine the activity concentration of atmospheric tritium by trapping tritium in air by bubbling through a water solution. Atmospheric tritium activity concentration levels are expressed in becquerel per cubic metre (Bq∙m<sup>-3</sup>).</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">The formulae are given for a sampling system with four bubblers. They can also be applied to trapping systems with only one trapping module consisting of two bubblers if only tritiated water vapour (HTO) is in the atmosphere to be sampled.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document does not cover laboratory test sample results, in becquerel per litre of trapping solution, according to <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">9698</span></span> or <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">13168</span></span>.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">The test method detection limit result is between 0,2 Bq∙m<sup>-3</sup> and 0,5 Bq∙m<sup>-3</sup> when the sampling duration is about one week.</span></p>
Registration number (WIID)73961
Scope<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document describes a test method to determine the activity concentration of atmospheric tritium by trapping tritium in air by bubbling through a water solution. Atmospheric tritium activity concentration levels are expressed in becquerel per cubic metre (Bq∙m<sup>-3</sup>).</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">The formulae are given for a sampling system with four bubblers. They can also be applied to trapping systems with only one trapping module consisting of two bubblers if only tritiated water vapour (HTO) is in the atmosphere to be sampled.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document does not cover laboratory test sample results, in becquerel per litre of trapping solution, according to <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">9698</span></span> or <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">13168</span></span>.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">The test method detection limit result is between 0,2 Bq∙m<sup>-3</sup> and 0,5 Bq∙m<sup>-3</sup> when the sampling duration is about one week.</span></p>
StatusStandarts spēkā
ICS group13.040.01
17.240