Project No.ISO 2889:2023
Title<p class="MsoBodyText"><span lang="EN-GB">This document sets forth performance-based criteria and recommendations for the design and use of systems for sampling of airborne radioactive materials in the effluent air from the ducts and stacks of nuclear facilities.</span></p> <p class="MsoBodyText"><span lang="EN-GB">The requirements and recommendations of this document are aimed at sampling that is conducted for regulatory compliance and system control. If existing air-sampling systems are not designed to the performance requirements and recommendations of this document, an evaluation of the performance of the system is advised. If deficiencies are discovered, a determination of whether or not a retrofit is needed and practicable is recommended.</span></p> <p class="MsoBodyText"><span lang="EN-GB">It can be impossible to meet the requirements of this document in all conditions with a sampling system designed for normal operations only. Under off-normal conditions, the criteria or recommendations of this document still apply. However, for accident conditions, special accident air sampling systems or measurements can be used.</span></p> <p class="MsoBodyText"><span lang="EN-GB">This document does not address outdoor air sampling, radon measurements, or the surveillance of airborne radioactive substances in the workplace of nuclear facilities.</span></p> <p class="Note"><span lang="EN-GB">NOTE<span style="mso-tab-count: 1;">            </span>Reference [1] addresses the instrumentation that is frequently used in nuclear air monitoring. Reference [5] addresses air sampling in the workplace of nuclear facilities. References [6] and [7] describe the performance characteristics of air monitors.</span></p>
Registration number (WIID)85248
Scope<p class="MsoBodyText"><span lang="EN-GB">This document sets forth performance-based criteria and recommendations for the design and use of systems for sampling of airborne radioactive materials in the effluent air from the ducts and stacks of nuclear facilities.</span></p> <p class="MsoBodyText"><span lang="EN-GB">The requirements and recommendations of this document are aimed at sampling that is conducted for regulatory compliance and system control. If existing air-sampling systems are not designed to the performance requirements and recommendations of this document, an evaluation of the performance of the system is advised. If deficiencies are discovered, a determination of whether or not a retrofit is needed and practicable is recommended.</span></p> <p class="MsoBodyText"><span lang="EN-GB">It can be impossible to meet the requirements of this document in all conditions with a sampling system designed for normal operations only. Under off-normal conditions, the criteria or recommendations of this document still apply. However, for accident conditions, special accident air sampling systems or measurements can be used.</span></p> <p class="MsoBodyText"><span lang="EN-GB">This document does not address outdoor air sampling, radon measurements, or the surveillance of airborne radioactive substances in the workplace of nuclear facilities.</span></p> <p class="Note"><span lang="EN-GB">NOTE<span style="mso-tab-count: 1;">            </span>Reference [1] addresses the instrumentation that is frequently used in nuclear air monitoring. Reference [5] addresses air sampling in the workplace of nuclear facilities. References [6] and [7] describe the performance characteristics of air monitors.</span></p>
StatusStandarts spēkā
ICS group13.280