Title<p>This document describes hydraulic performance tests (including cavitation tests) using a small size pump (centrifugal, mixed flow or axial pump, hereinafter referred to as a "model pump").</p> <p>This document is used for pump acceptance tests with a geometrically similar model pump to guarantee the performance of a large size pump manufactured for practical use (hereinafter, a "prototype pump"). This document, however does not preclude a temporary assembly inspection or other tests on the prototype pump. Moreover, it is preferable to conduct the tests with prototype pumps unless</p> <p>— the capacity of the pump, namely its flow rate and/or its power input, is beyond the limitations of the test facility, though it is difficult to set a criterion for carrying out a model pump test instead of the prototype pump test in terms of the volume rate of flow or the power input,</p> <p>— a part of the pump is to be constructed by concrete walls and reproduction of the whole assembly is impractical,</p> <p>— model tests are specified by the purchaser, or</p> <p>— it is difficult to carry out the prototype pump test due to any other reasons.</p> <p>This document applies to performance tests under steady operating conditions corresponding to the prototype pump.</p>
Registration number (WIID)66015
Scope<p>This document describes hydraulic performance tests (including cavitation tests) using a small size pump (centrifugal, mixed flow or axial pump, hereinafter referred to as a "model pump").</p> <p>This document is used for pump acceptance tests with a geometrically similar model pump to guarantee the performance of a large size pump manufactured for practical use (hereinafter, a "prototype pump"). This document, however does not preclude a temporary assembly inspection or other tests on the prototype pump. Moreover, it is preferable to conduct the tests with prototype pumps unless</p> <p>— the capacity of the pump, namely its flow rate and/or its power input, is beyond the limitations of the test facility, though it is difficult to set a criterion for carrying out a model pump test instead of the prototype pump test in terms of the volume rate of flow or the power input,</p> <p>— a part of the pump is to be constructed by concrete walls and reproduction of the whole assembly is impractical,</p> <p>— model tests are specified by the purchaser, or</p> <p>— it is difficult to carry out the prototype pump test due to any other reasons.</p> <p>This document applies to performance tests under steady operating conditions corresponding to the prototype pump.</p>
StatusStandarts spēkā
ICS group23.080