Project No.ISO 15002:2023
Title<p class="p2" style="tab-stops: 19.85pt 28.1pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document specifies requirements for <em style="mso-bidi-font-style: normal;">flow control devices</em> that can be connected by the user either directly, by means of a probe or a <em style="mso-bidi-font-style: normal;">gas-specific</em> connector, or indirectly by means of a low-pressure hose assembly conforming with <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">5359</span></span> to:</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">a)<span style="mso-tab-count: 1;">    </span>a terminal unit conforming with <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">9170</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span> of a medical gas pipeline system conforming with <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">7396</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span>:<span class="stdyear"><span style="color: black; mso-color-alt: windowtext;">2016</span></span>;</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">b)<span style="mso-tab-count: 1;">    </span>the pressure outlet of a regulator conforming with <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">10524</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span>:<span class="stdyear"><span style="color: black; mso-color-alt: windowtext;">2018</span></span>; or</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">c)<span style="mso-tab-count: 1;">    </span>to the pressure outlet of a valve integrated pressure regulator (VIPR) conforming with <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">10524</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">3</span></span> (see <span class="citesec"><span style="color: black; mso-color-alt: windowtext;">5.2</span></span> gas inlets).</span></p> <p class="p2" style="tab-stops: 19.85pt 28.1pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document applies to the following types of <em style="mso-bidi-font-style: normal;">flow control devices</em> (FCDs):</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">a)<span style="mso-tab-count: 1;">    </span><em style="mso-bidi-font-style: normal;">flowmeters</em>;</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">b)<span style="mso-tab-count: 1;">    </span><em style="mso-bidi-font-style: normal;">flowgauge FCDs</em>; and</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">c)<span style="mso-tab-count: 1;">    </span><em style="mso-bidi-font-style: normal;">fixed orifice FCDs</em>.</span></p> <p class="Note" style="line-height: 12.0pt; tab-stops: 19.85pt 39.7pt 48.25pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">NOTE<span style="mso-tab-count: 1;">       </span><em style="mso-bidi-font-style: normal;">Flow control devices</em> that are classed as medical electrical equipment can be subject to additional requirements of <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">IEC</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">60601</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span>.</span></p> <p class="p2" style="tab-stops: 19.85pt 28.1pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document applies to <em style="mso-bidi-font-style: normal;">flow control devices</em> for the following gases:</span></p> <p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;">    </span>oxygen;</span></p> <p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;">    </span>oxygen 93 %;</span></p> <p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;">    </span>nitrous oxide;</span></p> <p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;">    </span>medical air;</span></p> <p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="FR" style="mso-bidi-font-size: 12.0pt; mso-ansi-language: FR;">—<span style="mso-tab-count: 1;">    </span>carbon dioxide;</span></p> <p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="FR" style="mso-bidi-font-size: 12.0pt; mso-ansi-language: FR;">—<span style="mso-tab-count: 1;">    </span>oxygen/nitrous oxide mixture 50/50 (% volume fraction);</span></p> <p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;">    </span>oxygen-enriched air;</span></p> <p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;">    </span>helium;</span></p> <p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;">    </span>xenon; and</span></p> <p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;">    </span>specified mixtures of the gases listed above.</span></p> <p class="Note" style="tab-stops: 19.85pt 39.7pt 48.25pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">NOTE <em style="mso-bidi-font-style: normal;">Flow control devices</em> can be available for other gases.</span></p> <p class="p2" style="tab-stops: 19.85pt 28.1pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document does not apply to <em style="mso-bidi-font-style: normal;">flow control devices</em> that are:</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">a)<span style="mso-tab-count: 1;">    </span>for use with gases for driving surgical tools;</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">b)<span style="mso-tab-count: 1;">    </span>an integral part of a regulator (see <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">10524</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span>:<span class="stdyear"><span style="color: black; mso-color-alt: windowtext;">2018</span></span>); or</span></p> <p><span lang="EN-GB" style="font-size: 11.0pt; mso-bidi-font-size: 12.0pt; font-family: 'Cambria',serif; mso-fareast-font-family: 'MS Mincho'; mso-bidi-font-family: 'Times New Roman'; mso-ansi-language: EN-GB; mso-fareast-language: JA; mso-bidi-language: AR-SA;">c)<span style="mso-tab-count: 1;">           </span>an integral part of a valve with integrated pressure regulator (VIPR) (see <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">10524</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">3</span></span>).</span></p>
Registration number (WIID)75973
Scope<p class="p2" style="tab-stops: 19.85pt 28.1pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document specifies requirements for <em style="mso-bidi-font-style: normal;">flow control devices</em> that can be connected by the user either directly, by means of a probe or a <em style="mso-bidi-font-style: normal;">gas-specific</em> connector, or indirectly by means of a low-pressure hose assembly conforming with <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">5359</span></span> to:</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">a)<span style="mso-tab-count: 1;">    </span>a terminal unit conforming with <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">9170</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span> of a medical gas pipeline system conforming with <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">7396</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span>:<span class="stdyear"><span style="color: black; mso-color-alt: windowtext;">2016</span></span>;</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">b)<span style="mso-tab-count: 1;">    </span>the pressure outlet of a regulator conforming with <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">10524</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span>:<span class="stdyear"><span style="color: black; mso-color-alt: windowtext;">2018</span></span>; or</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">c)<span style="mso-tab-count: 1;">    </span>to the pressure outlet of a valve integrated pressure regulator (VIPR) conforming with <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">10524</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">3</span></span> (see <span class="citesec"><span style="color: black; mso-color-alt: windowtext;">5.2</span></span> gas inlets).</span></p> <p class="p2" style="tab-stops: 19.85pt 28.1pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document applies to the following types of <em style="mso-bidi-font-style: normal;">flow control devices</em> (FCDs):</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">a)<span style="mso-tab-count: 1;">    </span><em style="mso-bidi-font-style: normal;">flowmeters</em>;</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">b)<span style="mso-tab-count: 1;">    </span><em style="mso-bidi-font-style: normal;">flowgauge FCDs</em>; and</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">c)<span style="mso-tab-count: 1;">    </span><em style="mso-bidi-font-style: normal;">fixed orifice FCDs</em>.</span></p> <p class="Note" style="line-height: 12.0pt; tab-stops: 19.85pt 39.7pt 48.25pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">NOTE<span style="mso-tab-count: 1;">       </span><em style="mso-bidi-font-style: normal;">Flow control devices</em> that are classed as medical electrical equipment can be subject to additional requirements of <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">IEC</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">60601</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span>.</span></p> <p class="p2" style="tab-stops: 19.85pt 28.1pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document applies to <em style="mso-bidi-font-style: normal;">flow control devices</em> for the following gases:</span></p> <p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;">    </span>oxygen;</span></p> <p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;">    </span>oxygen 93 %;</span></p> <p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;">    </span>nitrous oxide;</span></p> <p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;">    </span>medical air;</span></p> <p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="FR" style="mso-bidi-font-size: 12.0pt; mso-ansi-language: FR;">—<span style="mso-tab-count: 1;">    </span>carbon dioxide;</span></p> <p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="FR" style="mso-bidi-font-size: 12.0pt; mso-ansi-language: FR;">—<span style="mso-tab-count: 1;">    </span>oxygen/nitrous oxide mixture 50/50 (% volume fraction);</span></p> <p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;">    </span>oxygen-enriched air;</span></p> <p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;">    </span>helium;</span></p> <p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;">    </span>xenon; and</span></p> <p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;">    </span>specified mixtures of the gases listed above.</span></p> <p class="Note" style="tab-stops: 19.85pt 39.7pt 48.25pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">NOTE <em style="mso-bidi-font-style: normal;">Flow control devices</em> can be available for other gases.</span></p> <p class="p2" style="tab-stops: 19.85pt 28.1pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document does not apply to <em style="mso-bidi-font-style: normal;">flow control devices</em> that are:</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">a)<span style="mso-tab-count: 1;">    </span>for use with gases for driving surgical tools;</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">b)<span style="mso-tab-count: 1;">    </span>an integral part of a regulator (see <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">10524</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span>:<span class="stdyear"><span style="color: black; mso-color-alt: windowtext;">2018</span></span>); or</span></p> <p><span lang="EN-GB" style="font-size: 11.0pt; mso-bidi-font-size: 12.0pt; font-family: 'Cambria',serif; mso-fareast-font-family: 'MS Mincho'; mso-bidi-font-family: 'Times New Roman'; mso-ansi-language: EN-GB; mso-fareast-language: JA; mso-bidi-language: AR-SA;">c)<span style="mso-tab-count: 1;">           </span>an integral part of a valve with integrated pressure regulator (VIPR) (see <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">10524</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">3</span></span>).</span></p>
StatusStandarts spēkā
ICS group11.040.10