Project No.ISO/TS 12869-2:2024
Title<p class="MsoBodyText"><span lang="EN-GB">This document provides the guidelines, minimum requirements and performance characteristics intended to guarantee that manufactured systems intended for on-site/field use (i.e. outside the laboratory) provide reliable and reproducible results.</span></p> <p class="MsoBodyText"><span lang="EN-GB">This document specifies the requirements for technologies that enable on-site detection and quantification of <em style="mso-bidi-font-style: normal;">Legionella</em> spp. and <em style="mso-bidi-font-style: normal;">L. pneumophila</em> using a quantitative polymerase chain reaction assay (qPCR). It specifies general methodological requirements, performance evaluation requirements and quality control requirements. This document is intended to be used by manufacturers of these technologies so that they produce detection systems that end users can operate safely and effectively. End users will be guided by this document to adhere to manufacturer’s instructions, to ensure user competency and to perform the necessary controls.</span></p> <p class="MsoBodyText"><span lang="EN-GB">Technical details specified in this document are given for information only. Any other technical solutions complying with the performance requirements are suitable.</span></p> <p class="Note"><span lang="EN-GB">NOTE<span style="mso-tab-count: 1;">          </span>For validation and performance requirements, see Clause 9.</span></p> <p class="MsoBodyText"><span lang="EN-GB">This document is intended to be applied in the bacteriological investigation of all types of water (hot or cold water, cooling tower water, etc.), unless the nature and/or content of suspended matter and/or background microorganisms interfere with the determination. This interference can result in an adverse effect on both the detection limit and the quantification limit.</span></p> <p class="MsoBodyText"><span lang="EN-GB">The results are expressed as the number of genome units of <em style="mso-bidi-font-style: normal;">Legionella</em> spp. and/or <em style="mso-bidi-font-style: normal;">L. pneumophila</em> per millilitre (or litre) of sample.</span></p> <p class="MsoBodyText"><span lang="EN-GB">Although the method described in this document is applicable to all types of water, some additives, such as chemicals used for water treatment, can interfere with and/or affect the sensitivity of the method.</span></p> <p class="MsoBodyText"><span lang="EN-GB">The qPCR methods do not give any information about the physiological state of the <em style="mso-bidi-font-style: normal;">Legionella.</em> However, there are on-site qPCR methodologies which are able to distinguish intact bacteria from free DNA. </span></p>
Registration number (WIID)84053
Scope<p class="MsoBodyText"><span lang="EN-GB">This document provides the guidelines, minimum requirements and performance characteristics intended to guarantee that manufactured systems intended for on-site/field use (i.e. outside the laboratory) provide reliable and reproducible results.</span></p> <p class="MsoBodyText"><span lang="EN-GB">This document specifies the requirements for technologies that enable on-site detection and quantification of <em style="mso-bidi-font-style: normal;">Legionella</em> spp. and <em style="mso-bidi-font-style: normal;">L. pneumophila</em> using a quantitative polymerase chain reaction assay (qPCR). It specifies general methodological requirements, performance evaluation requirements and quality control requirements. This document is intended to be used by manufacturers of these technologies so that they produce detection systems that end users can operate safely and effectively. End users will be guided by this document to adhere to manufacturer’s instructions, to ensure user competency and to perform the necessary controls.</span></p> <p class="MsoBodyText"><span lang="EN-GB">Technical details specified in this document are given for information only. Any other technical solutions complying with the performance requirements are suitable.</span></p> <p class="Note"><span lang="EN-GB">NOTE<span style="mso-tab-count: 1;">          </span>For validation and performance requirements, see Clause 9.</span></p> <p class="MsoBodyText"><span lang="EN-GB">This document is intended to be applied in the bacteriological investigation of all types of water (hot or cold water, cooling tower water, etc.), unless the nature and/or content of suspended matter and/or background microorganisms interfere with the determination. This interference can result in an adverse effect on both the detection limit and the quantification limit.</span></p> <p class="MsoBodyText"><span lang="EN-GB">The results are expressed as the number of genome units of <em style="mso-bidi-font-style: normal;">Legionella</em> spp. and/or <em style="mso-bidi-font-style: normal;">L. pneumophila</em> per millilitre (or litre) of sample.</span></p> <p class="MsoBodyText"><span lang="EN-GB">Although the method described in this document is applicable to all types of water, some additives, such as chemicals used for water treatment, can interfere with and/or affect the sensitivity of the method.</span></p> <p class="MsoBodyText"><span lang="EN-GB">The qPCR methods do not give any information about the physiological state of the <em style="mso-bidi-font-style: normal;">Legionella.</em> However, there are on-site qPCR methodologies which are able to distinguish intact bacteria from free DNA. </span></p>
StatusStandarts spēkā
ICS group07.100.20