<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: SimSun;">This document specifies the requirements and test methods for factory-made cellular glass products, which are used for thermal insulation of building equipment and industrial installations, with an operating temperature range of approximately −265 °C to +430 °C. The products are manufactured in the form of slabs, faced or unfaced boards, pipe sections, segments and prefabricated ware.</span></p>
<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: SimSun;">This document describes product characteristics and test methods, designation code, marking and labelling.</span></p>
<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: SimSun;">This document does not apply to:</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><em style="mso-bidi-font-style: normal;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: SimSun;">—</span></em><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: SimSun;"><span style="mso-tab-count: 1;"> </span>products with a declared thermal conductivity greater than 0,065 W/(m·K) at 10 °C;</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><em style="mso-bidi-font-style: normal;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: SimSun;">—</span></em><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: SimSun;"><span style="mso-tab-count: 1;"> </span>products for the insulation of the building structure.</span></p>
<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: SimSun;">This document does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. Specific requirements agreed between the purchaser and the supplier (e.g. type, dimensions and forms, regulatory compliance and inspection requirements or certification requirements), are outside the scope of this document.</span></p>
Registration number (WIID)
78330
Scope
<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: SimSun;">This document specifies the requirements and test methods for factory-made cellular glass products, which are used for thermal insulation of building equipment and industrial installations, with an operating temperature range of approximately −265 °C to +430 °C. The products are manufactured in the form of slabs, faced or unfaced boards, pipe sections, segments and prefabricated ware.</span></p>
<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: SimSun;">This document describes product characteristics and test methods, designation code, marking and labelling.</span></p>
<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: SimSun;">This document does not apply to:</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><em style="mso-bidi-font-style: normal;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: SimSun;">—</span></em><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: SimSun;"><span style="mso-tab-count: 1;"> </span>products with a declared thermal conductivity greater than 0,065 W/(m·K) at 10 °C;</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><em style="mso-bidi-font-style: normal;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: SimSun;">—</span></em><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: SimSun;"><span style="mso-tab-count: 1;"> </span>products for the insulation of the building structure.</span></p>
<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: SimSun;">This document does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. Specific requirements agreed between the purchaser and the supplier (e.g. type, dimensions and forms, regulatory compliance and inspection requirements or certification requirements), are outside the scope of this document.</span></p>