Projekta Nr.LVS EN ISO 16371-2:2018
NosaukumsThis European Standard specifies fundamental techniques of computed radiography with the aim of enabling satisfactory and repeatable results to be obtained economically. The techniques are based on the fundamental theory of the subject and tests measurements. This document specifies the general rules for industrial computed X- and gamma radiography for flaw detection purposes, using storage phosphor imaging plates (IP). It is based on the general principles for radiographic examination of metallic materials on the basis of films (ISO 5579). The basic set-up of radiation source, detector and the corresponding geometry shall be applied in agreement with ISO 5579 and the corresponding product standards as e.g. ISO 17636 for welding and EN 12681 for foundry. It does not lay down acceptance criteria of the imperfections. Digital detectors provide a digital grey value image which can be viewed and evaluated on basis of a computer only. This practice describes the recommended procedure for detector selection and radiographic practice. Selection of computer, software, monitor, printer and viewing conditions are important but not in the main focus of this standard. The procedure specified by this standard, provides the minimum requirements and practice which permits to expose and acquire digital radiographs with equivalent sensitivity for detection of imperfections as film radiography and as specified in ISO 5579.
Reģistrācijas numurs (WIID)59839
Darbības sfēraThis European Standard specifies fundamental techniques of computed radiography with the aim of enabling satisfactory and repeatable results to be obtained economically. The techniques are based on the fundamental theory of the subject and tests measurements. This document specifies the general rules for industrial computed X- and gamma radiography for flaw detection purposes, using storage phosphor imaging plates (IP). It is based on the general principles for radiographic examination of metallic materials on the basis of films (ISO 5579). The basic set-up of radiation source, detector and the corresponding geometry shall be applied in agreement with ISO 5579 and the corresponding product standards as e.g. ISO 17636 for welding and EN 12681 for foundry. It does not lay down acceptance criteria of the imperfections. Digital detectors provide a digital grey value image which can be viewed and evaluated on basis of a computer only. This practice describes the recommended procedure for detector selection and radiographic practice. Selection of computer, software, monitor, printer and viewing conditions are important but not in the main focus of this standard. The procedure specified by this standard, provides the minimum requirements and practice which permits to expose and acquire digital radiographs with equivalent sensitivity for detection of imperfections as film radiography and as specified in ISO 5579.
StatussStandarts spēkā
ICS grupa19.100