Informējam, ka Sistēma pielāgota darbam ar interneta pārlūkprogrammu Internet Explorer (8. un jaunākām versijām) un Mozilla Firefox (3.6 un jaunākām versijām).
Izmantojot citu interneta pārlūkprogrammu, brīdinām, ka Sistēmas funkcionalitāte var tikt traucēta.
This European standard specifies a method for the measurement of effective focal spot dimensions above 0,1 µm of X-ray systems by means of the edge method applied to digital images taken from hole type or disk type gauges. The imaging quality and the resolution of X-ray images depend highly on the characteristics of the effective focal spot, in particular the size and the two-dimensional intensity distribution as seen from the detector plane.
This document provides instructions for determining the effective size (dimensions) of standard, mini and micro focal spots of industrial X-ray tubes for users in applications where the pin hole method of EN12543-2 is not practicable. This determination is based on the measurement of a profile of an image of a hole or disk type gauge.
The method as described in this document can be used for long term monitoring of focal spot sizes without a pin hole camera.
The accuracy of this method is lower than the one of ISO 32543-1 (EN 12543-2), ISO/NP 32543-3 (EN 12543-5) and ISO/NP 32543-4 (future EN 12543-6), using ASTM hole plate IQIs (ASTM E 1025, E 1742), due to its manufacturer tolerance of 10%.
Reģistrācijas numurs (WIID)
79151
Darbības sfēra
This European standard specifies a method for the measurement of effective focal spot dimensions above 0,1 µm of X-ray systems by means of the edge method applied to digital images taken from hole type or disk type gauges. The imaging quality and the resolution of X-ray images depend highly on the characteristics of the effective focal spot, in particular the size and the two-dimensional intensity distribution as seen from the detector plane.
This document provides instructions for determining the effective size (dimensions) of standard, mini and micro focal spots of industrial X-ray tubes for users in applications where the pin hole method of EN12543-2 is not practicable. This determination is based on the measurement of a profile of an image of a hole or disk type gauge.
The method as described in this document can be used for long term monitoring of focal spot sizes without a pin hole camera.
The accuracy of this method is lower than the one of ISO 32543-1 (EN 12543-2), ISO/NP 32543-3 (EN 12543-5) and ISO/NP 32543-4 (future EN 12543-6), using ASTM hole plate IQIs (ASTM E 1025, E 1742), due to its manufacturer tolerance of 10%.