CLC/TC 17AC
| Projekta Nr. | EN IEC 62271-102:2018 |
|---|---|
| Nosaukums | IEC 62271-102:2018 applies to alternating current disconnectors and earthing switches, designed for indoor and outdoor installations for nominal voltages above 1 000 V and for service frequencies up to and including 60 Hz. This second edition cancels and replaces the first edition published in 2001, Amendment 1:2011 and Amendment 2:2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: <ol style="list-style-type:lower-alpha"> <li>new numbering according to IEC 17/1025/RQ to harmonize with ISO/IEC Directives, Part 2, and IEEE Std. C37.100.1;</li> <li>clause numbering has been aligned with IEC 62271-1:2017;</li> <li>the Scope has been extended to cover all indoor and outdoor installations. Consideration of switching devices having disconnecting and/or earthing switch functionalities, apart from other functions, are also covered by this document;</li> <li>ratings have been moved from Annexes B, C and E to Clause 5; the order of the subclauses now corresponds to the order of subclauses in Clause 7;</li> <li>new rating values for bus-transfer current and bus-transfer voltage have been assigned;</li> <li>new class of mechanical endurance for earthing switches has been added (M1);</li> <li>subclause "Rated values of electrical endurance for earthing switches" is now called "Classification of earthing switches for short-circuit making capability";</li> <li>new subclause with ratings for ice-coating has been added;</li> <li>new subclause with classification of bus-charging switching capability has been added;</li> <li>new withstand requirements for interlocking devices have been added;</li> <li>the way to comply with the requirements of the isolating distance of disconnectors has been modified;</li> <li>design and construction requirements for position-indicating devices have been modified, aligning the requirements for position indication and signalling;</li> <li>the value of the operating force has been changed;</li> <li>the test procedures and validation criteria have been revised and modified where necessary;</li> <li>requirements for applied voltage during single-phase test on non-simultaneous closing earthing switches have been changed;</li> <li>non-verifiable requirements have been deleted;</li> <li>a new subclause has been added for testing mechanical interlocking devices;</li> <li>the high- and low-temperature test is mandatory if the temperature limits for the service conditions of the apparatus (defined by the manufacturer) are above +40 °C or below −5 °C, and a more detailed testing procedure is given;</li> <li>the testing procedure to verify the proper functioning of the position-indicating device allows a more practicable testing for every technology used;</li> <li>a new Annex B has been added with title: "Current-switching capability required of disconnectors and earthing switches";</li> <li>a new Annex C has been added with title: "Tolerances on test quantities for type tests";</li> <li>a new Annex E has been added with title: "Extension of validity of type tests".</li> </ol> |
| Reģistrācijas numurs (WIID) | 63193 |
| Darbības sfēra | IEC 62271-102:2018 applies to alternating current disconnectors and earthing switches, designed for indoor and outdoor installations for nominal voltages above 1 000 V and for service frequencies up to and including 60 Hz. This second edition cancels and replaces the first edition published in 2001, Amendment 1:2011 and Amendment 2:2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: <ol style="list-style-type:lower-alpha"> <li>new numbering according to IEC 17/1025/RQ to harmonize with ISO/IEC Directives, Part 2, and IEEE Std. C37.100.1;</li> <li>clause numbering has been aligned with IEC 62271-1:2017;</li> <li>the Scope has been extended to cover all indoor and outdoor installations. Consideration of switching devices having disconnecting and/or earthing switch functionalities, apart from other functions, are also covered by this document;</li> <li>ratings have been moved from Annexes B, C and E to Clause 5; the order of the subclauses now corresponds to the order of subclauses in Clause 7;</li> <li>new rating values for bus-transfer current and bus-transfer voltage have been assigned;</li> <li>new class of mechanical endurance for earthing switches has been added (M1);</li> <li>subclause "Rated values of electrical endurance for earthing switches" is now called "Classification of earthing switches for short-circuit making capability";</li> <li>new subclause with ratings for ice-coating has been added;</li> <li>new subclause with classification of bus-charging switching capability has been added;</li> <li>new withstand requirements for interlocking devices have been added;</li> <li>the way to comply with the requirements of the isolating distance of disconnectors has been modified;</li> <li>design and construction requirements for position-indicating devices have been modified, aligning the requirements for position indication and signalling;</li> <li>the value of the operating force has been changed;</li> <li>the test procedures and validation criteria have been revised and modified where necessary;</li> <li>requirements for applied voltage during single-phase test on non-simultaneous closing earthing switches have been changed;</li> <li>non-verifiable requirements have been deleted;</li> <li>a new subclause has been added for testing mechanical interlocking devices;</li> <li>the high- and low-temperature test is mandatory if the temperature limits for the service conditions of the apparatus (defined by the manufacturer) are above +40 °C or below −5 °C, and a more detailed testing procedure is given;</li> <li>the testing procedure to verify the proper functioning of the position-indicating device allows a more practicable testing for every technology used;</li> <li>a new Annex B has been added with title: "Current-switching capability required of disconnectors and earthing switches";</li> <li>a new Annex C has been added with title: "Tolerances on test quantities for type tests";</li> <li>a new Annex E has been added with title: "Extension of validity of type tests".</li> </ol> |
| Statuss | Izstrādē |
| ICS grupa | 29.130.10 29.130.99 |