Informējam, ka Sistēma pielāgota darbam ar interneta pārlūkprogrammu Internet Explorer (8. un jaunākām versijām) un Mozilla Firefox (3.6 un jaunākām versijām).
Izmantojot citu interneta pārlūkprogrammu, brīdinām, ka Sistēmas funkcionalitāte var tikt traucēta.
Provide specification and requirements to enable interoperability of freight wagons, freight locomotives, and external power
supply with digital automatic coupler (DAC) on the European railway network.
Specification of the DAC electrical coupler interfaces for use in rail freight operation:
- Interoperability interface specification of the electric coupler: contact properties, electrical connector etc. taking into account the
contact requirements from the respective standard for data communication
- Parameters of the voltage supply network: voltage type, level, electrical current, tolerances etc.
- Insulation, electric safety, and electromagnetic compatibility requirements
- Requirements for power cable, cable routing from coupler to wagon, protection for power and communication cable, using the
communication cable defined in the respective standard for data communication
- Electrical interface from coupler cable to the wagon
- Requirements due to functional safety goals
- Test methods for the electric coupler and the coupler cable
Reģistrācijas numurs (WIID)
79346
Darbības sfēra
Provide specification and requirements to enable interoperability of freight wagons, freight locomotives, and external power
supply with digital automatic coupler (DAC) on the European railway network.
Specification of the DAC electrical coupler interfaces for use in rail freight operation:
- Interoperability interface specification of the electric coupler: contact properties, electrical connector etc. taking into account the
contact requirements from the respective standard for data communication
- Parameters of the voltage supply network: voltage type, level, electrical current, tolerances etc.
- Insulation, electric safety, and electromagnetic compatibility requirements
- Requirements for power cable, cable routing from coupler to wagon, protection for power and communication cable, using the
communication cable defined in the respective standard for data communication
- Electrical interface from coupler cable to the wagon
- Requirements due to functional safety goals
- Test methods for the electric coupler and the coupler cable