Projekta Nr.LVS EN 50588-1:2015
NosaukumsThis European Standard covers three-phase power transformers from 5 kVA up to 40 000 kVA for indoor or outdoor continuous service, 50 Hz with two windings, with a highest voltage for equipment [1,1 kV ≤ Um ≤ 36 kV] and at least one of the windings having a highest voltage for equipment not below [3,6 kV]. NOTE 1 Transformers with tap changer (DETC or OLTC) are included in this European Standard even if they have separate winding to make the taps. NOTE 2 This European Standard applies also for rated voltages less than 36kV where the highest voltage for equipment is 38,5 kV. The requirement are those for Um= 36kV. The object of this European Standard is to lay down requirements related to electrical characteristics and design of three-phase medium power transformers. The following transformers are excluded from this European Standard: - transformers, which have no windings with highest voltage for equipment (Um) higher than 1,1 kV; - instrument transformers; - tractions transformers mounted on rolling stock; - starting transformers; - testing transformers; - welding transformers; - transformers for deep water submerged application; - medium Voltage (MV) to Medium Voltage (MV) interface transformers up to 5 MVA; - transformers for converter applications; - transformers for furnace applications; - transformers for offshore applications and floating offshore applications; - transformers for emergency installations; - transformers and auto-transformers for railway feeding systems; - earthing transformers; - explosion-proof and underground mining transformers.
Reģistrācijas numurs (WIID)47743
Darbības sfēraThis European Standard covers three-phase power transformers from 5 kVA up to 40 000 kVA for indoor or outdoor continuous service, 50 Hz with two windings, with a highest voltage for equipment [1,1 kV ≤ Um ≤ 36 kV] and at least one of the windings having a highest voltage for equipment not below [3,6 kV]. NOTE 1 Transformers with tap changer (DETC or OLTC) are included in this European Standard even if they have separate winding to make the taps. NOTE 2 This European Standard applies also for rated voltages less than 36kV where the highest voltage for equipment is 38,5 kV. The requirement are those for Um= 36kV. The object of this European Standard is to lay down requirements related to electrical characteristics and design of three-phase medium power transformers. The following transformers are excluded from this European Standard: - transformers, which have no windings with highest voltage for equipment (Um) higher than 1,1 kV; - instrument transformers; - tractions transformers mounted on rolling stock; - starting transformers; - testing transformers; - welding transformers; - transformers for deep water submerged application; - medium Voltage (MV) to Medium Voltage (MV) interface transformers up to 5 MVA; - transformers for converter applications; - transformers for furnace applications; - transformers for offshore applications and floating offshore applications; - transformers for emergency installations; - transformers and auto-transformers for railway feeding systems; - earthing transformers; - explosion-proof and underground mining transformers.
StatussAtcelts
ICS grupa29.180