Projekta Nr.FprCEN/TS 16591
NosaukumsThis Technical Specification provides requirements and test methods for flexible, pre-insulated, directly buried heating pipe systems with in-situ cross-linkable polyethylene PE-Xb service pipes to be used for district heating. This Technical Specification is valid for systems with maximum operating temperatures of 95 °C and maximum operating pressures up to 6 bars and designed for a lifetime of at least 30 years. This Technical Specification does not cover surveillance systems.
Reģistrācijas numurs (WIID)35490
Darbības sfēraThis Technical Specification provides requirements and test methods for flexible, pre-insulated, directly buried heating pipe systems with in-situ cross-linkable polyethylene PE-Xb service pipes to be used for district heating. This Technical Specification is valid for systems with maximum operating temperatures of 95 °C and maximum operating pressures up to 6 bars and designed for a lifetime of at least 30 years. This Technical Specification does not cover surveillance systems.
StatussIzstrādē
ICS grupa23.040.01
23.040.07
23.040.20