Informējam, ka Sistēma pielāgota darbam ar interneta pārlūkprogrammu Internet Explorer (8. un jaunākām versijām) un Mozilla Firefox (3.6 un jaunākām versijām).
Izmantojot citu interneta pārlūkprogrammu, brīdinām, ka Sistēmas funkcionalitāte var tikt traucēta.
This document specifies the determination of the molar-mass distribution and the average molar mass values <em>M</em><sub>n</sub> (number average) and <em>M</em><sub>w</sub> (weight average) of polymers that are soluble in tetrahydrofuran (THF) by gel permeation chromatography (GPC).
NOTE Also known as size exclusion chromatography (SEC).
Even though the chromatograms obtained show good repeatability, it is possible that this method cannot be used with certain polymer types because of specific interactions (e.g. adsorption) within the sample/eluent/column system.
The conditions specified in this document are not applicable to the GPC analysis of polymer samples with <em>M</em><sub>w</sub> values greater than 10<sup>6</sup> g/mol and/or of polymers with elution limits outside the calibration range (see 7.6 and Annex C).
This document includes no correction method (e.g. for the elimination of peak broadening. If absolute molar-mass values are required, an absolute method (e.g. membrane osmometry for <em>M</em><sub>n</sub> or light scattering for <em>M</em><sub>w</sub>) can be used.
Reģistrācijas numurs (WIID)
84185
Darbības sfēra
This document specifies the determination of the molar-mass distribution and the average molar mass values <em>M</em><sub>n</sub> (number average) and <em>M</em><sub>w</sub> (weight average) of polymers that are soluble in tetrahydrofuran (THF) by gel permeation chromatography (GPC).
NOTE Also known as size exclusion chromatography (SEC).
Even though the chromatograms obtained show good repeatability, it is possible that this method cannot be used with certain polymer types because of specific interactions (e.g. adsorption) within the sample/eluent/column system.
The conditions specified in this document are not applicable to the GPC analysis of polymer samples with <em>M</em><sub>w</sub> values greater than 10<sup>6</sup> g/mol and/or of polymers with elution limits outside the calibration range (see 7.6 and Annex C).
This document includes no correction method (e.g. for the elimination of peak broadening. If absolute molar-mass values are required, an absolute method (e.g. membrane osmometry for <em>M</em><sub>n</sub> or light scattering for <em>M</em><sub>w</sub>) can be used.