This Europeanl Standard provides test methods and acceptance criteria for the evaluation of the electromagnetic compatibility of Earth-moving machinery as defined in ISO 6165 and Building and road-construction machines covered by ISO/TC 195.
Part 1 deals with General EMC requirements under typical EMC environmental conditions.
Functional safety requirements are covered in part 2 of ISO 13766.
Electrical and/or electronic component(s) or separate technical unit(s) intended to be fitted in construction machinery are also dealt with in this International Standard. The following electromagnetic disturbance phenomena are evaluated:
- broadband and narrowband electromagnetic interference;
- electromagnetic field immunity test;
- broadband and narrowband interference of electrical/electronic sub-assemblies;
- electromagnetic field immunity test of electrical/electronic sub-assemblies;
- electrostatic discharge;
- conducted transients.
Construction machinery can have DC and/or AC internal electrical power supply systems.
Machines that are designed to be supplied by the „Public Mains Network― are specifically excluded.
Reģistrācijas numurs (WIID)
60089
Darbības sfēra
This Europeanl Standard provides test methods and acceptance criteria for the evaluation of the electromagnetic compatibility of Earth-moving machinery as defined in ISO 6165 and Building and road-construction machines covered by ISO/TC 195.
Part 1 deals with General EMC requirements under typical EMC environmental conditions.
Functional safety requirements are covered in part 2 of ISO 13766.
Electrical and/or electronic component(s) or separate technical unit(s) intended to be fitted in construction machinery are also dealt with in this International Standard. The following electromagnetic disturbance phenomena are evaluated:
- broadband and narrowband electromagnetic interference;
- electromagnetic field immunity test;
- broadband and narrowband interference of electrical/electronic sub-assemblies;
- electromagnetic field immunity test of electrical/electronic sub-assemblies;
- electrostatic discharge;
- conducted transients.
Construction machinery can have DC and/or AC internal electrical power supply systems.
Machines that are designed to be supplied by the „Public Mains Network― are specifically excluded.