Informējam, ka Sistēma pielāgota darbam ar interneta pārlūkprogrammu Internet Explorer (8. un jaunākām versijām) un Mozilla Firefox (3.6 un jaunākām versijām).
Izmantojot citu interneta pārlūkprogrammu, brīdinām, ka Sistēmas funkcionalitāte var tikt traucēta.
1.1 This technical report contains recommendations for the design of pump intakes and the installation of pumps. As far as possible, these recommendations should be adhered to in order to obtain correct operation of the plant. These recommendations are applicable regardless of the flow rate of the plant : - plant which works with clear water (or relatively uncloudy) and relatively non-aerated water or any other liquid having physical and chemical properties which are similar to those of water ; NOTE This document nevertheless contains several general recommendations for operation with cloudy (or very cloudy) water. - Pumping plant which has its own floor. 1.2 This standard deals with various intake configurations : - clause 3 contains recommendations which apply to vertical intakes with a bellmouth ;
- clause 4 contains recommendations applicable to top intakes ; - clause 5 contains recommendations applicable to floor intakes ; - clause 6 contains recommendations applicable to side-wall intakes.
Reģistrācijas numurs (WIID)
9170
Darbības sfēra
1.1 This technical report contains recommendations for the design of pump intakes and the installation of pumps. As far as possible, these recommendations should be adhered to in order to obtain correct operation of the plant. These recommendations are applicable regardless of the flow rate of the plant : - plant which works with clear water (or relatively uncloudy) and relatively non-aerated water or any other liquid having physical and chemical properties which are similar to those of water ; NOTE This document nevertheless contains several general recommendations for operation with cloudy (or very cloudy) water. - Pumping plant which has its own floor. 1.2 This standard deals with various intake configurations : - clause 3 contains recommendations which apply to vertical intakes with a bellmouth ;
- clause 4 contains recommendations applicable to top intakes ; - clause 5 contains recommendations applicable to floor intakes ; - clause 6 contains recommendations applicable to side-wall intakes.