This document describes a test method for the recovery of soluble bitumen from bituminous mixtures from pavements in a form suitable for further testing. The procedure is suitable for the recovery of paving grade bitumen and is also suitable for mixtures containing volatile matter such as cut-back bitumen but the results may be less precise. This European Standard is the reference method for mixtures containing volatile matter, but the rotary evaporator procedure (see EN 12697-3) for mixtures with paving grade bitumen.
Reģistrācijas numurs (WIID)
36300
Darbības sfēra
This document describes a test method for the recovery of soluble bitumen from bituminous mixtures from pavements in a form suitable for further testing. The procedure is suitable for the recovery of paving grade bitumen and is also suitable for mixtures containing volatile matter such as cut-back bitumen but the results may be less precise. This European Standard is the reference method for mixtures containing volatile matter, but the rotary evaporator procedure (see EN 12697-3) for mixtures with paving grade bitumen.