1.1 This part of EN 13463 contains the specific requirements for the construction and testing of equipment with pressurized enclosures, of protection type "p", intended for use in explosive atmospheres.
The requirements contained in this standard are supplementary to those in EN 13463-1. The standard specifies requirements for equipment of categories M2, 2D, 2G and for equipment that does not comply with EN 13463-1 equipment categories 3G and 3D.
1.2 This standard specifies requirements for pressurized enclosures containing a limited release of a liquid or gas but not dust.
1.3 This standard does not contain the requirements for pressurized enclosures where the containment system may release
air with an oxygen content greater than normal, or
oxygen in combination with inert gas in a proportion greater than 21 %.
1.4 This standard does not contain requirements for pressurized rooms or analyser houses; see IEC/TR 60079-13 and IEC/TR 60079-16.
1.5 Due to the safety factors incorporated in the type of protection, the uncertainty of measurement inherent in good quality, regularly calibrated measurement equipment is considered to have no significant detrimental effect and need not be taken into account when making the measurements necessary to verify compliance of the apparatus with the requirements of this standard.
1.6 When the user acts in the role of the manufacturer, it is the user's responsibility to ensure that all relevant parts of this standard are applied to the manufacturing and testing of the apparatus.
Reģistrācijas numurs (WIID)
14907
Darbības sfēra
1.1 This part of EN 13463 contains the specific requirements for the construction and testing of equipment with pressurized enclosures, of protection type "p", intended for use in explosive atmospheres.
The requirements contained in this standard are supplementary to those in EN 13463-1. The standard specifies requirements for equipment of categories M2, 2D, 2G and for equipment that does not comply with EN 13463-1 equipment categories 3G and 3D.
1.2 This standard specifies requirements for pressurized enclosures containing a limited release of a liquid or gas but not dust.
1.3 This standard does not contain the requirements for pressurized enclosures where the containment system may release
air with an oxygen content greater than normal, or
oxygen in combination with inert gas in a proportion greater than 21 %.
1.4 This standard does not contain requirements for pressurized rooms or analyser houses; see IEC/TR 60079-13 and IEC/TR 60079-16.
1.5 Due to the safety factors incorporated in the type of protection, the uncertainty of measurement inherent in good quality, regularly calibrated measurement equipment is considered to have no significant detrimental effect and need not be taken into account when making the measurements necessary to verify compliance of the apparatus with the requirements of this standard.
1.6 When the user acts in the role of the manufacturer, it is the user's responsibility to ensure that all relevant parts of this standard are applied to the manufacturing and testing of the apparatus.