<p>This document specifies a potentiometric or visual titration method for the determination of manganese content in alloyed steels.</p>
<p>The method is applicable to manganese mass fractions between 2 % and 25 %. Vanadium and cerium interfere with the determination. If the mass fraction of cerium in the sample is less than 0,01 %, or the mass fraction of vanadium in the sample is less than 0,005 %, the interference is negligible, otherwise theoretical corrections are necessary.</p>
Reģistrācijas numurs (WIID)
73383
Darbības sfēra
<p>This document specifies a potentiometric or visual titration method for the determination of manganese content in alloyed steels.</p>
<p>The method is applicable to manganese mass fractions between 2 % and 25 %. Vanadium and cerium interfere with the determination. If the mass fraction of cerium in the sample is less than 0,01 %, or the mass fraction of vanadium in the sample is less than 0,005 %, the interference is negligible, otherwise theoretical corrections are necessary.</p>