Informējam, ka Sistēma pielāgota darbam ar interneta pārlūkprogrammu Internet Explorer (8. un jaunākām versijām) un Mozilla Firefox (3.6 un jaunākām versijām).
Izmantojot citu interneta pārlūkprogrammu, brīdinām, ka Sistēmas funkcionalitāte var tikt traucēta.
<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho';">This document specifies a method for determining the pour point of petroleum products by means of automated equipment, in which movement of the test specimen is detected using a step-wise cooling technique.</span></p>
<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho';">A separate procedure suitable for the determination of the lower pour point of fuel oils, heavy lubricant base stock, and products containing residual fuel components is also described.</span></p>
<p class="MsoBodyText" style="tab-stops: 19.85pt 39.7pt 48.25pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho';">The procedure described in this document is not suitable for crude oils.</span></p>
<p class="MsoBodyText" style="tab-stops: 19.85pt 39.7pt 48.25pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho';">Test results from this method are determined in 3 °C testing intervals.</span></p>
<p class="Note" style="line-height: 12.0pt; tab-stops: 19.85pt 39.7pt 48.25pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho';">NOTE<span style="mso-tab-count: 1;"> </span>Some equipment can also generate results at 1 °C testing intervals, which is an acceptable alternative procedure, but for which precision and bias have not been determined.</span></p>
Reģistrācijas numurs (WIID)
77257
Darbības sfēra
<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho';">This document specifies a method for determining the pour point of petroleum products by means of automated equipment, in which movement of the test specimen is detected using a step-wise cooling technique.</span></p>
<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho';">A separate procedure suitable for the determination of the lower pour point of fuel oils, heavy lubricant base stock, and products containing residual fuel components is also described.</span></p>
<p class="MsoBodyText" style="tab-stops: 19.85pt 39.7pt 48.25pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho';">The procedure described in this document is not suitable for crude oils.</span></p>
<p class="MsoBodyText" style="tab-stops: 19.85pt 39.7pt 48.25pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho';">Test results from this method are determined in 3 °C testing intervals.</span></p>
<p class="Note" style="line-height: 12.0pt; tab-stops: 19.85pt 39.7pt 48.25pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'MS Mincho';">NOTE<span style="mso-tab-count: 1;"> </span>Some equipment can also generate results at 1 °C testing intervals, which is an acceptable alternative procedure, but for which precision and bias have not been determined.</span></p>