Informējam, ka Sistēma pielāgota darbam ar interneta pārlūkprogrammu Internet Explorer (8. un jaunākām versijām) un Mozilla Firefox (3.6 un jaunākām versijām).
Izmantojot citu interneta pārlūkprogrammu, brīdinām, ka Sistēmas funkcionalitāte var tikt traucēta.
<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document describes the principle of electrochemical noise measurement (EN), specifically focusing on the application of the technique to indicate the level of protection provided by an organic coating to the underlying metal. It discusses the principles behind the measurement method but also the type of electrochemical apparatus, the experimental set-up and electrodes configurations, the presentation of measured data, and analysis of results that have been used in the work done so far and reported in the references. This work has mainly been done in the laboratory, and there are some examples of work conducted in the field.</span></p>
<p class="Note" style="tab-stops: 19.85pt 39.7pt 48.25pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">NOTE<span style="mso-tab-count: 1;"> </span>At the time of publication of this document, electrochemical noise measurement for coatings is mainly used by a number of academic groups. This document aims to encourage more general application of this method, particularly to field work.</span></p>
Reģistrācijas numurs (WIID)
87261
Darbības sfēra
<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document describes the principle of electrochemical noise measurement (EN), specifically focusing on the application of the technique to indicate the level of protection provided by an organic coating to the underlying metal. It discusses the principles behind the measurement method but also the type of electrochemical apparatus, the experimental set-up and electrodes configurations, the presentation of measured data, and analysis of results that have been used in the work done so far and reported in the references. This work has mainly been done in the laboratory, and there are some examples of work conducted in the field.</span></p>
<p class="Note" style="tab-stops: 19.85pt 39.7pt 48.25pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">NOTE<span style="mso-tab-count: 1;"> </span>At the time of publication of this document, electrochemical noise measurement for coatings is mainly used by a number of academic groups. This document aims to encourage more general application of this method, particularly to field work.</span></p>