<p>ISO 1136:2015 specifies a method for the determination of the mean diameter of wool fibres, using an apparatus which passes a current of air through a bundle of fibres.</p>
<p>This International Standard is applicable to clean, unmedullated wool fibres dispersed in a uniform, open state. It provides a method particularly suitable for combed slivers. The dichloromethane extractable matter content of the specimen must not exceed 1,0 %. It is applicable to oil-combed slivers after cleaning with an organic solvent.</p>
<p>The method described in this International Standard is less accurate for lambswool and for wool which is appreciably medullated (see Annex D) and heavily dyed wool.</p>
Reģistrācijas numurs (WIID)
61689
Darbības sfēra
<p>ISO 1136:2015 specifies a method for the determination of the mean diameter of wool fibres, using an apparatus which passes a current of air through a bundle of fibres.</p>
<p>This International Standard is applicable to clean, unmedullated wool fibres dispersed in a uniform, open state. It provides a method particularly suitable for combed slivers. The dichloromethane extractable matter content of the specimen must not exceed 1,0 %. It is applicable to oil-combed slivers after cleaning with an organic solvent.</p>
<p>The method described in this International Standard is less accurate for lambswool and for wool which is appreciably medullated (see Annex D) and heavily dyed wool.</p>