Informējam, ka Sistēma pielāgota darbam ar interneta pārlūkprogrammu Internet Explorer (8. un jaunākām versijām) un Mozilla Firefox (3.6 un jaunākām versijām).
Izmantojot citu interneta pārlūkprogrammu, brīdinām, ka Sistēmas funkcionalitāte var tikt traucēta.
<p>The principle of the method specified is dissolving a test portion in dimethylformamide and injecting a small volume of the solution into a gas chromatograph equipped with flame ionization detector to separate and detect the volatile components. The solvent contains a known amount of propionitrile or acetonitrile as an internal standard for quantitative evaluation. With this method, a lower detection limit of the order of 3 ppm of acrylonitrile in the copolymer may be expected. To obtain a lower detection limit of the order of 0,3 ppm to 0,4 ppm, an alternative method is specified in annex A.</p>
Reģistrācijas numurs (WIID)
10506
Darbības sfēra
<p>The principle of the method specified is dissolving a test portion in dimethylformamide and injecting a small volume of the solution into a gas chromatograph equipped with flame ionization detector to separate and detect the volatile components. The solvent contains a known amount of propionitrile or acetonitrile as an internal standard for quantitative evaluation. With this method, a lower detection limit of the order of 3 ppm of acrylonitrile in the copolymer may be expected. To obtain a lower detection limit of the order of 0,3 ppm to 0,4 ppm, an alternative method is specified in annex A.</p>