<p class="MsoBodyText"><span lang="EN-GB">This document specifies two methods to assess the quality of sealed anodic oxidation coatings on aluminium and its alloys:</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">Method 1 which assesses the quality of sealed anodic oxidation coatings by measuring the loss of mass after immersion in a phosphoric acid based solution without prior acid treatment;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">Method 2 which assesses the quality of sealed anodic oxidation coatings by measuring the loss of mass after immersion in a phosphoric acid based solution with prior acid treatment.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">Method 1 is applicable to anodic oxidation coatings intended for decorative or protective purposes or where resistance to staining is important.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">Method 2 is applicable to anodic oxidation coatings intended for outdoor architectural purposes. For less severe applications, Method 1 can be more suitable.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">The methods are not applicable to the following:</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">hard-type anodic oxidation coatings which normally are not sealed;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">anodic oxidation coatings that have been sealed only in dichromate solutions;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">anodic oxidation coatings produced in chromic acid solutions;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">anodic oxidation coatings that have undergone treatment to render them hydrophobic.</span></p>
<p class="Note"><span lang="EN-GB">NOTE 1<span style="mso-tab-count: 1;"> </span>While the methods assess the quality of hydrothermal sealing applied to anodized aluminium, they can be appropriate for other sealing methods.</span></p>
<p class="Note"><span lang="EN-GB">NOTE 2<span style="mso-tab-count: 1;"> </span>The methods are destructive and can serve as reference methods in case of doubt or dispute regarding the results of the test for loss of absorptive power (see ISO 2143) or the measurement of admittance (see ISO 2931).</span></p>
Reģistrācijas numurs (WIID)
88866
Darbības sfēra
<p class="MsoBodyText"><span lang="EN-GB">This document specifies two methods to assess the quality of sealed anodic oxidation coatings on aluminium and its alloys:</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">Method 1 which assesses the quality of sealed anodic oxidation coatings by measuring the loss of mass after immersion in a phosphoric acid based solution without prior acid treatment;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">Method 2 which assesses the quality of sealed anodic oxidation coatings by measuring the loss of mass after immersion in a phosphoric acid based solution with prior acid treatment.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">Method 1 is applicable to anodic oxidation coatings intended for decorative or protective purposes or where resistance to staining is important.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">Method 2 is applicable to anodic oxidation coatings intended for outdoor architectural purposes. For less severe applications, Method 1 can be more suitable.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">The methods are not applicable to the following:</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">hard-type anodic oxidation coatings which normally are not sealed;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">anodic oxidation coatings that have been sealed only in dichromate solutions;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">anodic oxidation coatings produced in chromic acid solutions;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">anodic oxidation coatings that have undergone treatment to render them hydrophobic.</span></p>
<p class="Note"><span lang="EN-GB">NOTE 1<span style="mso-tab-count: 1;"> </span>While the methods assess the quality of hydrothermal sealing applied to anodized aluminium, they can be appropriate for other sealing methods.</span></p>
<p class="Note"><span lang="EN-GB">NOTE 2<span style="mso-tab-count: 1;"> </span>The methods are destructive and can serve as reference methods in case of doubt or dispute regarding the results of the test for loss of absorptive power (see ISO 2143) or the measurement of admittance (see ISO 2931).</span></p>