Nosaukums<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document specifies test methods for the evaluation of dental restorative materials, luting materials, fissure sealants and orthodontic bonding or luting materials that are claimed by their respective manufacturers to exert “antibacterial” effects.</span></p> <p class="Note" style="tab-stops: 19.85pt 39.7pt 48.25pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">NOTE<span style="mso-tab-count: 1;">       </span>Materials for pulp capping (e.g. calcium hydroxide formulations), endodontic filling materials, dental implants or implant systems, nightguards and additive manufactured (e.g. 3D-printed) materials are not covered in this document.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document does not cover tests on the effectiveness of sterilization or disinfection procedures. This document cannot be used to demonstrate a lack of microbial contamination of medical devices used in dentistry.</span></p>
Reģistrācijas numurs (WIID)79697
Darbības sfēra<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document specifies test methods for the evaluation of dental restorative materials, luting materials, fissure sealants and orthodontic bonding or luting materials that are claimed by their respective manufacturers to exert “antibacterial” effects.</span></p> <p class="Note" style="tab-stops: 19.85pt 39.7pt 48.25pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">NOTE<span style="mso-tab-count: 1;">       </span>Materials for pulp capping (e.g. calcium hydroxide formulations), endodontic filling materials, dental implants or implant systems, nightguards and additive manufactured (e.g. 3D-printed) materials are not covered in this document.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document does not cover tests on the effectiveness of sterilization or disinfection procedures. This document cannot be used to demonstrate a lack of microbial contamination of medical devices used in dentistry.</span></p>
StatussStandarts spēkā
ICS grupa11.060.10