<p class="MsoBodyText"><span lang="EN-GB">This document specifies laboratory testing methods for electrically powered air circulating fan heads and ceiling fans when air is used as the test gas. </span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document is applicable to air circulating fans with an input power greater than or equal to 125 W, except for ceiling fans that are larger than 1 800 mm, which do not have a lower input power limit. The diameter of the fan being tested is limited by the minimum dimensions as shown in the applicable test figures.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">See annex A for information on common names used for various air circulating fans.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document does not apply to:</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">jet fans;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">powered roof ventilators, induced flow fans, laboratory exhausts;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">positive pressure ventilators as defined in ISO 24660:2024;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">compressors;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">positive displacement machines.</span></p>
Reģistrācijas numurs (WIID)
86894
Darbības sfēra
<p class="MsoBodyText"><span lang="EN-GB">This document specifies laboratory testing methods for electrically powered air circulating fan heads and ceiling fans when air is used as the test gas. </span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document is applicable to air circulating fans with an input power greater than or equal to 125 W, except for ceiling fans that are larger than 1 800 mm, which do not have a lower input power limit. The diameter of the fan being tested is limited by the minimum dimensions as shown in the applicable test figures.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">See annex A for information on common names used for various air circulating fans.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document does not apply to:</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">jet fans;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">powered roof ventilators, induced flow fans, laboratory exhausts;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">positive pressure ventilators as defined in ISO 24660:2024;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">compressors;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">positive displacement machines.</span></p>