<p class="p2"><span lang="EN-GB">This document provides the essential requirements for the design of <em style="mso-bidi-font-style: normal;">supralaryngeal airways</em> and <em style="mso-bidi-font-style: normal;">connectors</em>. These devices are intended to provide a distinct respiratory pathway to the top of the larynx to provide an unobstructed airway in patients during spontaneous, assisted or controlled ventilation.</span></p>
<p class="p2"><span lang="EN-GB">This document specifies the dimensions, basic properties and method of size designation of the available types of <em style="mso-bidi-font-style: normal;">supralaryngeal airways</em>. Airways devised for specialized applications are not specifically covered, although most may be classified by the sizing and dimensions (or other characteristics) required by this document.</span></p>
<p class="p2"><span lang="EN-GB">The following devices are outside the scope of this document: nasal and oropharyngeal airways, anesthetic masks, oro- and naso-tracheal tubes, cricothyrotomy devices, dental appliances, tracheal stents, tracheal tubes, ventilating laryngoscopes, CPAP devices, esophageal obturators, bougies and devices that require surgical placement.</span></p>
<p class="p2"><span lang="EN-GB">This document specifies dimensional disclosure so the operator will know which auxiliary devices, such as tracheal tubes and bronchoscopes will be size-compatible.</span></p>
<p class="p2"><span lang="EN-GB">Flammability of airways, for example if used with certain flammable anesthetic gases, electrosurgical units or lasers, is a well-recognized hazard that is outside the scope of this document. (See E.1.7).</span></p>
<p class="p2"> </p>
Reģistrācijas numurs (WIID)
81539
Darbības sfēra
<p class="p2"><span lang="EN-GB">This document provides the essential requirements for the design of <em style="mso-bidi-font-style: normal;">supralaryngeal airways</em> and <em style="mso-bidi-font-style: normal;">connectors</em>. These devices are intended to provide a distinct respiratory pathway to the top of the larynx to provide an unobstructed airway in patients during spontaneous, assisted or controlled ventilation.</span></p>
<p class="p2"><span lang="EN-GB">This document specifies the dimensions, basic properties and method of size designation of the available types of <em style="mso-bidi-font-style: normal;">supralaryngeal airways</em>. Airways devised for specialized applications are not specifically covered, although most may be classified by the sizing and dimensions (or other characteristics) required by this document.</span></p>
<p class="p2"><span lang="EN-GB">The following devices are outside the scope of this document: nasal and oropharyngeal airways, anesthetic masks, oro- and naso-tracheal tubes, cricothyrotomy devices, dental appliances, tracheal stents, tracheal tubes, ventilating laryngoscopes, CPAP devices, esophageal obturators, bougies and devices that require surgical placement.</span></p>
<p class="p2"><span lang="EN-GB">This document specifies dimensional disclosure so the operator will know which auxiliary devices, such as tracheal tubes and bronchoscopes will be size-compatible.</span></p>
<p class="p2"><span lang="EN-GB">Flammability of airways, for example if used with certain flammable anesthetic gases, electrosurgical units or lasers, is a well-recognized hazard that is outside the scope of this document. (See E.1.7).</span></p>
<p class="p2"> </p>