×
Informējam, ka Sistēma pielāgota darbam ar interneta pārlūkprogrammu Internet Explorer (8. un jaunākām versijām) un Mozilla Firefox (3.6 un jaunākām versijām).
Izmantojot citu interneta pārlūkprogrammu, brīdinām, ka Sistēmas funkcionalitāte var tikt traucēta.
Projekta Nr. ISO 15002:2023
Nosaukums <p class="p2" style="tab-stops: 19.85pt 28.1pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document specifies requirements for <em style="mso-bidi-font-style: normal;">flow control devices</em> that can be connected by the user either directly, by means of a probe or a <em style="mso-bidi-font-style: normal;">gas-specific</em> connector, or indirectly by means of a low-pressure hose assembly conforming with <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">5359</span></span> to:</span></p>
<p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">a)<span style="mso-tab-count: 1;"> </span>a terminal unit conforming with <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">9170</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span> of a medical gas pipeline system conforming with <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">7396</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span>:<span class="stdyear"><span style="color: black; mso-color-alt: windowtext;">2016</span></span>;</span></p>
<p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">b)<span style="mso-tab-count: 1;"> </span>the pressure outlet of a regulator conforming with <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">10524</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span>:<span class="stdyear"><span style="color: black; mso-color-alt: windowtext;">2018</span></span>; or</span></p>
<p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">c)<span style="mso-tab-count: 1;"> </span>to the pressure outlet of a valve integrated pressure regulator (VIPR) conforming with <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">10524</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">3</span></span> (see <span class="citesec"><span style="color: black; mso-color-alt: windowtext;">5.2</span></span> gas inlets).</span></p>
<p class="p2" style="tab-stops: 19.85pt 28.1pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document applies to the following types of <em style="mso-bidi-font-style: normal;">flow control devices</em> (FCDs):</span></p>
<p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">a)<span style="mso-tab-count: 1;"> </span><em style="mso-bidi-font-style: normal;">flowmeters</em>;</span></p>
<p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">b)<span style="mso-tab-count: 1;"> </span><em style="mso-bidi-font-style: normal;">flowgauge FCDs</em>; and</span></p>
<p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">c)<span style="mso-tab-count: 1;"> </span><em style="mso-bidi-font-style: normal;">fixed orifice FCDs</em>.</span></p>
<p class="Note" style="line-height: 12.0pt; tab-stops: 19.85pt 39.7pt 48.25pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">NOTE<span style="mso-tab-count: 1;"> </span><em style="mso-bidi-font-style: normal;">Flow control devices</em> that are classed as medical electrical equipment can be subject to additional requirements of <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">IEC</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">60601</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span>.</span></p>
<p class="p2" style="tab-stops: 19.85pt 28.1pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document applies to <em style="mso-bidi-font-style: normal;">flow control devices</em> for the following gases:</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>oxygen;</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>oxygen 93 %;</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>nitrous oxide;</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>medical air;</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="FR" style="mso-bidi-font-size: 12.0pt; mso-ansi-language: FR;">—<span style="mso-tab-count: 1;"> </span>carbon dioxide;</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="FR" style="mso-bidi-font-size: 12.0pt; mso-ansi-language: FR;">—<span style="mso-tab-count: 1;"> </span>oxygen/nitrous oxide mixture 50/50 (% volume fraction);</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>oxygen-enriched air;</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>helium;</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>xenon; and</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>specified mixtures of the gases listed above.</span></p>
<p class="Note" style="tab-stops: 19.85pt 39.7pt 48.25pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">NOTE <em style="mso-bidi-font-style: normal;">Flow control devices</em> can be available for other gases.</span></p>
<p class="p2" style="tab-stops: 19.85pt 28.1pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document does not apply to <em style="mso-bidi-font-style: normal;">flow control devices</em> that are:</span></p>
<p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">a)<span style="mso-tab-count: 1;"> </span>for use with gases for driving surgical tools;</span></p>
<p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">b)<span style="mso-tab-count: 1;"> </span>an integral part of a regulator (see <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">10524</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span>:<span class="stdyear"><span style="color: black; mso-color-alt: windowtext;">2018</span></span>); or</span></p>
<p><span lang="EN-GB" style="font-size: 11.0pt; mso-bidi-font-size: 12.0pt; font-family: 'Cambria',serif; mso-fareast-font-family: 'MS Mincho'; mso-bidi-font-family: 'Times New Roman'; mso-ansi-language: EN-GB; mso-fareast-language: JA; mso-bidi-language: AR-SA;">c)<span style="mso-tab-count: 1;"> </span>an integral part of a valve with integrated pressure regulator (VIPR) (see <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">10524</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">3</span></span>).</span></p>
Reģistrācijas numurs (WIID) 75973
Darbības sfēra <p class="p2" style="tab-stops: 19.85pt 28.1pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document specifies requirements for <em style="mso-bidi-font-style: normal;">flow control devices</em> that can be connected by the user either directly, by means of a probe or a <em style="mso-bidi-font-style: normal;">gas-specific</em> connector, or indirectly by means of a low-pressure hose assembly conforming with <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">5359</span></span> to:</span></p>
<p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">a)<span style="mso-tab-count: 1;"> </span>a terminal unit conforming with <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">9170</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span> of a medical gas pipeline system conforming with <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">7396</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span>:<span class="stdyear"><span style="color: black; mso-color-alt: windowtext;">2016</span></span>;</span></p>
<p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">b)<span style="mso-tab-count: 1;"> </span>the pressure outlet of a regulator conforming with <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">10524</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span>:<span class="stdyear"><span style="color: black; mso-color-alt: windowtext;">2018</span></span>; or</span></p>
<p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">c)<span style="mso-tab-count: 1;"> </span>to the pressure outlet of a valve integrated pressure regulator (VIPR) conforming with <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">10524</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">3</span></span> (see <span class="citesec"><span style="color: black; mso-color-alt: windowtext;">5.2</span></span> gas inlets).</span></p>
<p class="p2" style="tab-stops: 19.85pt 28.1pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document applies to the following types of <em style="mso-bidi-font-style: normal;">flow control devices</em> (FCDs):</span></p>
<p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">a)<span style="mso-tab-count: 1;"> </span><em style="mso-bidi-font-style: normal;">flowmeters</em>;</span></p>
<p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">b)<span style="mso-tab-count: 1;"> </span><em style="mso-bidi-font-style: normal;">flowgauge FCDs</em>; and</span></p>
<p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">c)<span style="mso-tab-count: 1;"> </span><em style="mso-bidi-font-style: normal;">fixed orifice FCDs</em>.</span></p>
<p class="Note" style="line-height: 12.0pt; tab-stops: 19.85pt 39.7pt 48.25pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">NOTE<span style="mso-tab-count: 1;"> </span><em style="mso-bidi-font-style: normal;">Flow control devices</em> that are classed as medical electrical equipment can be subject to additional requirements of <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">IEC</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">60601</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span>.</span></p>
<p class="p2" style="tab-stops: 19.85pt 28.1pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document applies to <em style="mso-bidi-font-style: normal;">flow control devices</em> for the following gases:</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>oxygen;</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>oxygen 93 %;</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>nitrous oxide;</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>medical air;</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="FR" style="mso-bidi-font-size: 12.0pt; mso-ansi-language: FR;">—<span style="mso-tab-count: 1;"> </span>carbon dioxide;</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="FR" style="mso-bidi-font-size: 12.0pt; mso-ansi-language: FR;">—<span style="mso-tab-count: 1;"> </span>oxygen/nitrous oxide mixture 50/50 (% volume fraction);</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>oxygen-enriched air;</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>helium;</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>xenon; and</span></p>
<p class="ListContinue1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>specified mixtures of the gases listed above.</span></p>
<p class="Note" style="tab-stops: 19.85pt 39.7pt 48.25pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">NOTE <em style="mso-bidi-font-style: normal;">Flow control devices</em> can be available for other gases.</span></p>
<p class="p2" style="tab-stops: 19.85pt 28.1pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document does not apply to <em style="mso-bidi-font-style: normal;">flow control devices</em> that are:</span></p>
<p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">a)<span style="mso-tab-count: 1;"> </span>for use with gases for driving surgical tools;</span></p>
<p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">b)<span style="mso-tab-count: 1;"> </span>an integral part of a regulator (see <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">10524</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span>:<span class="stdyear"><span style="color: black; mso-color-alt: windowtext;">2018</span></span>); or</span></p>
<p><span lang="EN-GB" style="font-size: 11.0pt; mso-bidi-font-size: 12.0pt; font-family: 'Cambria',serif; mso-fareast-font-family: 'MS Mincho'; mso-bidi-font-family: 'Times New Roman'; mso-ansi-language: EN-GB; mso-fareast-language: JA; mso-bidi-language: AR-SA;">c)<span style="mso-tab-count: 1;"> </span>an integral part of a valve with integrated pressure regulator (VIPR) (see <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">10524</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">3</span></span>).</span></p>
Statuss Standarts spēkā
ICS grupa 11.040.10