Projekta Nr.ISO 23369:2022
Nosaukums<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document specifies:</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">a)<span style="mso-tab-count: 1;">    </span>A multi-pass filtration performance test under cyclic flow conditions with continuous contaminant injection for hydraulic fluid power filter elements.</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">b)<span style="mso-tab-count: 1;">    </span>A procedure for determining the contaminant capacity, particulate removal and differential pressure characteristics.</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">c)<span style="mso-tab-count: 1;">    </span>A test currently applicable to hydraulic fluid power filter elements that exhibit an average filtration ratio greater than or equal to 75 for particle sizes ≤25 µm(c), and a final test system reservoir gravimetric level of less than 200 mg/L. It is necessary to determine by validation the range of flow rates and the lower particle size limit that can be used in test facilities.</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">d)<span style="mso-tab-count: 1;">    </span>A test using <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">ISO</span></span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">12103</span></span></span>‑<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">1</span></span></span> A3 medium test dust contaminant and a test fluid.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document provides a test procedure that yields reproducible test data for appraising the filtration performance of a hydraulic fluid power filter element without influence of electrostatic charge.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document is applicable to three test conditions:</span></p> <p class="ListContinue1"><span lang="EN-GB">—<span style="mso-tab-count: 1;">    </span>Base upstream gravimetric level of 3 mg/L;</span></p> <p class="ListContinue1"><span lang="EN-GB">—<span style="mso-tab-count: 1;">    </span>Base upstream gravimetric level of 10 mg/L;</span></p> <p class="ListContinue1"><span lang="EN-GB">—<span style="mso-tab-count: 1;">    </span>Base upstream gravimetric level of 15 mg/L.</span></p>
Reģistrācijas numurs (WIID)84020
Darbības sfēra<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document specifies:</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">a)<span style="mso-tab-count: 1;">    </span>A multi-pass filtration performance test under cyclic flow conditions with continuous contaminant injection for hydraulic fluid power filter elements.</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">b)<span style="mso-tab-count: 1;">    </span>A procedure for determining the contaminant capacity, particulate removal and differential pressure characteristics.</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">c)<span style="mso-tab-count: 1;">    </span>A test currently applicable to hydraulic fluid power filter elements that exhibit an average filtration ratio greater than or equal to 75 for particle sizes ≤25 µm(c), and a final test system reservoir gravimetric level of less than 200 mg/L. It is necessary to determine by validation the range of flow rates and the lower particle size limit that can be used in test facilities.</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">d)<span style="mso-tab-count: 1;">    </span>A test using <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">ISO</span></span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">12103</span></span></span>‑<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">1</span></span></span> A3 medium test dust contaminant and a test fluid.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document provides a test procedure that yields reproducible test data for appraising the filtration performance of a hydraulic fluid power filter element without influence of electrostatic charge.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document is applicable to three test conditions:</span></p> <p class="ListContinue1"><span lang="EN-GB">—<span style="mso-tab-count: 1;">    </span>Base upstream gravimetric level of 3 mg/L;</span></p> <p class="ListContinue1"><span lang="EN-GB">—<span style="mso-tab-count: 1;">    </span>Base upstream gravimetric level of 10 mg/L;</span></p> <p class="ListContinue1"><span lang="EN-GB">—<span style="mso-tab-count: 1;">    </span>Base upstream gravimetric level of 15 mg/L.</span></p>
StatussStandarts spēkā
ICS grupa23.100.60