Projekta Nr.ISO 16890-3:2016
Nosaukums<p>ISO 16890-3:2016 specifies the test equipment and the test methods used for measuring the gravimetric efficiency and resistance to air flow of air filter for general ventilation.</p> <p>It is intended for use in conjunction with ISO 16890‑1, ISO 16890‑2 and ISO 16890‑4.</p> <p>The test method described in this part of ISO 16890 is applicable for air flow rates between 0,25 m3/s (900 m3/h, 530 ft3/min) and 1,5 m3/s (5 400 m3/h, 3 178 ft3/min), referring to a test rig with a nominal face area of 610 mm × 610 mm (24 in × 24 in).</p> <p>ISO 16890 (all parts) refers to particulate air filter elements for general ventilation having an ePM1 efficiency less than or equal to 99 % and an ePM10 efficiency greater than 20 % when tested as per the procedures defined within ISO 16890 (all parts).</p> <p>Air filter elements outside of this aerosol fraction are evaluated by other applicable test methods. See ISO 29463 (all parts).</p> <p>Filter elements used in portable room-air cleaners are excluded from the scope of this part of ISO 16890.</p> <p>The performance results obtained in accordance with ISO 16890 (all parts) cannot by themselves be quantitatively applied to predict performance in service with regard to efficiency and lifetime.</p>
Reģistrācijas numurs (WIID)57866
Darbības sfēra<p>ISO 16890-3:2016 specifies the test equipment and the test methods used for measuring the gravimetric efficiency and resistance to air flow of air filter for general ventilation.</p> <p>It is intended for use in conjunction with ISO 16890‑1, ISO 16890‑2 and ISO 16890‑4.</p> <p>The test method described in this part of ISO 16890 is applicable for air flow rates between 0,25 m3/s (900 m3/h, 530 ft3/min) and 1,5 m3/s (5 400 m3/h, 3 178 ft3/min), referring to a test rig with a nominal face area of 610 mm × 610 mm (24 in × 24 in).</p> <p>ISO 16890 (all parts) refers to particulate air filter elements for general ventilation having an ePM1 efficiency less than or equal to 99 % and an ePM10 efficiency greater than 20 % when tested as per the procedures defined within ISO 16890 (all parts).</p> <p>Air filter elements outside of this aerosol fraction are evaluated by other applicable test methods. See ISO 29463 (all parts).</p> <p>Filter elements used in portable room-air cleaners are excluded from the scope of this part of ISO 16890.</p> <p>The performance results obtained in accordance with ISO 16890 (all parts) cannot by themselves be quantitatively applied to predict performance in service with regard to efficiency and lifetime.</p>
StatussAtcelts
ICS grupa91.140.30