Projekta Nr.ISO 16000-41:2023
Nosaukums<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document specifies a procedure for the assessment of the indoor air quality that is valid for all interior rooms in residential and non-residential buildings with natural or mechanical ventilation, in which people do not only stay temporarily.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document is applicable to indoor environments as defined in <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">16000</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span>.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">The assessment of working materials in workrooms or workplaces in buildings, that are subject to statutory occupational safety specifications, are excluded from this document. In these rooms, only air constituents that do not originate from working materials can be assessed according to this document.</span></p> <p class="MsoBodyText" style="line-height: 11.5pt; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">It is not possible to define classes with exact values for the individual pollutants, as the corresponding limit and guide values differ in individual countries. In addition, the values relate to different observation periods.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">Aspects concerning electromagnetic fields, noise and vibrations and their effect on the indoor air quality are not the object of this document. The classification of further consequences and measures, such as organisational steps, structural engineering measures, renovation proposals, further human medicine appraisals and the like, are not the object of this document.</span></p> <p class="Note" style="tab-stops: 19.85pt 39.7pt 48.25pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">NOTE<span style="mso-tab-count: 1;">       </span>This document applies to of all types of indoor environments occupied by all kinds of persons, including regular users, clients and workers.</span></p>
Reģistrācijas numurs (WIID)76519
Darbības sfēra<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document specifies a procedure for the assessment of the indoor air quality that is valid for all interior rooms in residential and non-residential buildings with natural or mechanical ventilation, in which people do not only stay temporarily.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document is applicable to indoor environments as defined in <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext;">ISO</span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext;">16000</span></span>-<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext;">1</span></span>.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">The assessment of working materials in workrooms or workplaces in buildings, that are subject to statutory occupational safety specifications, are excluded from this document. In these rooms, only air constituents that do not originate from working materials can be assessed according to this document.</span></p> <p class="MsoBodyText" style="line-height: 11.5pt; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">It is not possible to define classes with exact values for the individual pollutants, as the corresponding limit and guide values differ in individual countries. In addition, the values relate to different observation periods.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">Aspects concerning electromagnetic fields, noise and vibrations and their effect on the indoor air quality are not the object of this document. The classification of further consequences and measures, such as organisational steps, structural engineering measures, renovation proposals, further human medicine appraisals and the like, are not the object of this document.</span></p> <p class="Note" style="tab-stops: 19.85pt 39.7pt 48.25pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">NOTE<span style="mso-tab-count: 1;">       </span>This document applies to of all types of indoor environments occupied by all kinds of persons, including regular users, clients and workers.</span></p>
StatussStandarts spēkā
ICS grupa13.040.20