Projekta Nr.ISO 16478:2023
Nosaukums<p class="MsoBodyText"><span lang="EN-GB">This document:</span></p> <p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';">     </span></span></span><!--[endif]--><span lang="EN-GB">defines requirements for vacuum insulation panels (VIPs) with silica or glass fibre core, which are used for thermal insulation of buildings;</span></p> <p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';">     </span></span></span><!--[endif]--><span lang="EN-GB">outlines required product properties, their performance, test methods and rules for conformity evaluations, identification and labelling;</span></p> <p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';">     </span></span></span><!--[endif]--><span lang="EN-GB">provides a test method to determine ageing factors and the influence of the linear thermal bridges at the edges.</span></p> <p class="MsoBodyText"><span lang="EN-GB">This document is applicable to all types of silica and glass fibre core VIPs, independent of the type of envelope. In the case of a glass fibre core VIP, it is only applicable to VIPs with desiccants whose service life is ≥ 25 years.</span></p> <p class="MsoBodyText"><span lang="EN-GB">This document is not applicable to:</span></p> <p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';">     </span></span></span><!--[endif]--><span lang="EN-GB">any specific installation and application requirements;</span></p> <p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';">     </span></span></span><!--[endif]--><span lang="EN-GB">products intended to be used for the insulation of building equipment and industrial installations.</span></p>
Reģistrācijas numurs (WIID)78555
Darbības sfēra<p class="MsoBodyText"><span lang="EN-GB">This document:</span></p> <p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';">     </span></span></span><!--[endif]--><span lang="EN-GB">defines requirements for vacuum insulation panels (VIPs) with silica or glass fibre core, which are used for thermal insulation of buildings;</span></p> <p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';">     </span></span></span><!--[endif]--><span lang="EN-GB">outlines required product properties, their performance, test methods and rules for conformity evaluations, identification and labelling;</span></p> <p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';">     </span></span></span><!--[endif]--><span lang="EN-GB">provides a test method to determine ageing factors and the influence of the linear thermal bridges at the edges.</span></p> <p class="MsoBodyText"><span lang="EN-GB">This document is applicable to all types of silica and glass fibre core VIPs, independent of the type of envelope. In the case of a glass fibre core VIP, it is only applicable to VIPs with desiccants whose service life is ≥ 25 years.</span></p> <p class="MsoBodyText"><span lang="EN-GB">This document is not applicable to:</span></p> <p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';">     </span></span></span><!--[endif]--><span lang="EN-GB">any specific installation and application requirements;</span></p> <p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';">     </span></span></span><!--[endif]--><span lang="EN-GB">products intended to be used for the insulation of building equipment and industrial installations.</span></p>
StatussStandarts spēkā
ICS grupa91.100.60