Projekta Nr.ISO 24323:2023
Nosaukums<p class="MsoBodyText"><span lang="EN-GB">The design method provided in this document addresses vibration induced by walking action of occupants and covers the following timber floor systems:</span></p> <p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">a)<span style="font: 7.0pt 'Times New Roman';">       </span></span></span><!--[endif]--><span lang="EN-GB">Light frame floors built with timber joists spaced at a distance of no more than 610 mm with a layer of structural wood-based subfloor that is connected to the joists using mechanical fasteners or adhesive. The area density of a bare light frame floors without a screed (topping) and ceiling is not greater than 25 kg/m<sup>2</sup>. Figure 1 shows such a light frame floor.</span></p> <p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">b)<span style="font: 7.0pt 'Times New Roman';">       </span></span></span><!--[endif]--><span lang="EN-GB">Mass timber floors built with mass timber panels such as cross laminated timber (CLT).</span></p> <p class="MsoBodyText"><span lang="EN-GB">This document consists of three elements:</span></p> <p class="ListNumber1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">a)<span style="font: 7.0pt 'Times New Roman';">       </span></span></span><!--[endif]--><span lang="EN-GB">a baseline vibrational serviceability design criterion for timber floors using fundamental natural frequency and 1 kN static point load deflection as the design parameters including two types of design criteria, coupled and decoupled criteria;</span></p> <p class="ListNumber1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">b)<span style="font: 7.0pt 'Times New Roman';">       </span></span></span><!--[endif]--><span lang="EN-GB">equations for calculating the design parameters;</span></p> <p class="ListNumber1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">c)<span style="font: 7.0pt 'Times New Roman';">        </span></span></span><!--[endif]--><span lang="EN-GB">guidelines for the design values of the physical and mechanical properties of floor components.</span></p> <p class="MsoBodyText"><span lang="EN-GB">The design method is based on the assumption that the floor system has a single span and simple support conditions.</span></p>
Reģistrācijas numurs (WIID)78430
Darbības sfēra<p class="MsoBodyText"><span lang="EN-GB">The design method provided in this document addresses vibration induced by walking action of occupants and covers the following timber floor systems:</span></p> <p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">a)<span style="font: 7.0pt 'Times New Roman';">       </span></span></span><!--[endif]--><span lang="EN-GB">Light frame floors built with timber joists spaced at a distance of no more than 610 mm with a layer of structural wood-based subfloor that is connected to the joists using mechanical fasteners or adhesive. The area density of a bare light frame floors without a screed (topping) and ceiling is not greater than 25 kg/m<sup>2</sup>. Figure 1 shows such a light frame floor.</span></p> <p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">b)<span style="font: 7.0pt 'Times New Roman';">       </span></span></span><!--[endif]--><span lang="EN-GB">Mass timber floors built with mass timber panels such as cross laminated timber (CLT).</span></p> <p class="MsoBodyText"><span lang="EN-GB">This document consists of three elements:</span></p> <p class="ListNumber1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">a)<span style="font: 7.0pt 'Times New Roman';">       </span></span></span><!--[endif]--><span lang="EN-GB">a baseline vibrational serviceability design criterion for timber floors using fundamental natural frequency and 1 kN static point load deflection as the design parameters including two types of design criteria, coupled and decoupled criteria;</span></p> <p class="ListNumber1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">b)<span style="font: 7.0pt 'Times New Roman';">       </span></span></span><!--[endif]--><span lang="EN-GB">equations for calculating the design parameters;</span></p> <p class="ListNumber1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">c)<span style="font: 7.0pt 'Times New Roman';">        </span></span></span><!--[endif]--><span lang="EN-GB">guidelines for the design values of the physical and mechanical properties of floor components.</span></p> <p class="MsoBodyText"><span lang="EN-GB">The design method is based on the assumption that the floor system has a single span and simple support conditions.</span></p>
StatussStandarts spēkā
ICS grupa91.080.20