<p class="MsoBodyText"><span lang="EN-GB">This document specifies requirements for the components of glued laminated bamboo members intended for structural use.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">Although currently most glued laminated bamboo is made from <em style="mso-bidi-font-style: normal;">Phyllostachys edulis</em> (Moso), this document also applies to other bamboo species (e.g. <em style="mso-bidi-font-style: normal;">Guadua angustifolia</em>, <em style="mso-bidi-font-style: normal;">Dendrocalamus asper</em>) if the performance required by this document can be shown to have been achieved.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">The basic requirements apply to structural members of all service classes; however, special precautions are necessary for service class 3, for example, the use of weather resistant adhesives (see 5.2).</span></p>
<p class="MsoBodyText"><span lang="EN-GB">Annex C contains informative references for formaldehyde emission.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">The requirements will need to be supplemented to take into consideration any relevant special conditions as well as material and/or functional requirements.</span></p>
Reģistrācijas numurs (WIID)
83076
Darbības sfēra
<p class="MsoBodyText"><span lang="EN-GB">This document specifies requirements for the components of glued laminated bamboo members intended for structural use.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">Although currently most glued laminated bamboo is made from <em style="mso-bidi-font-style: normal;">Phyllostachys edulis</em> (Moso), this document also applies to other bamboo species (e.g. <em style="mso-bidi-font-style: normal;">Guadua angustifolia</em>, <em style="mso-bidi-font-style: normal;">Dendrocalamus asper</em>) if the performance required by this document can be shown to have been achieved.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">The basic requirements apply to structural members of all service classes; however, special precautions are necessary for service class 3, for example, the use of weather resistant adhesives (see 5.2).</span></p>
<p class="MsoBodyText"><span lang="EN-GB">Annex C contains informative references for formaldehyde emission.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">The requirements will need to be supplemented to take into consideration any relevant special conditions as well as material and/or functional requirements.</span></p>