<p class="MsoBodyText"><span lang="EN-GB">This document specifies the measurement method used for calculating the temperature coefficient of the refractive index by measuring the refractive index, which changes with the temperature of the optical glass using the minimum deviation method.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">The intended temperature range for the specified measurement method is –40 °C to +80 °C.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">The intended wavelength range for the specified measurement method is 365 nm to 1 014 nm.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">The intended accuracy for the specified measurement method is 1 × 10<sup>-6</sup> K<sup>-1</sup>.</span></p>
Reģistrācijas numurs (WIID)
90228
Darbības sfēra
<p class="MsoBodyText"><span lang="EN-GB">This document specifies the measurement method used for calculating the temperature coefficient of the refractive index by measuring the refractive index, which changes with the temperature of the optical glass using the minimum deviation method.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">The intended temperature range for the specified measurement method is –40 °C to +80 °C.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">The intended wavelength range for the specified measurement method is 365 nm to 1 014 nm.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">The intended accuracy for the specified measurement method is 1 × 10<sup>-6</sup> K<sup>-1</sup>.</span></p>