×
Informējam, ka Sistēma pielāgota darbam ar interneta pārlūkprogrammu Internet Explorer (8. un jaunākām versijām) un Mozilla Firefox (3.6 un jaunākām versijām).
Izmantojot citu interneta pārlūkprogrammu, brīdinām, ka Sistēmas funkcionalitāte var tikt traucēta.
Projekta Nr. ISO 10943:2023
Nosaukums <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="FR" style="mso-bidi-font-size: 12.0pt;">Le présent document, conjointement avec les <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">ISO</span></span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">15004</span></span></span>‑<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">1</span></span></span> et <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">ISO</span></span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">15004</span></span></span>‑<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">2</span></span></span>, spécifie les exigences minimales et les méthodes d’essai relatives aux ophtalmoscopes indirects à maniement manuel, de type binoculaire porté sur la tête, conçus pour l’observation indirecte des images du fond de l’œil.</span></p>
<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="FR" style="mso-bidi-font-size: 12.0pt;">Le présent document a la priorité sur l’<span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">ISO</span></span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">15004</span></span></span>‑<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">1</span></span></span> et l’<span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">ISO</span></span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">15004</span></span></span>‑<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">2</span></span></span> lorsque des différences existent.</span></p>
<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="FR" style="mso-bidi-font-size: 12.0pt;">Il ne s’applique pas aux lentilles convergentes utilisées en ophtalmoscopie indirecte, ni aux accessoires.</span></p>
<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="FR" style="mso-bidi-font-size: 12.0pt;">Le présent document ne s’applique pas aux instruments montés sur table tels que les ophtalmoscopes de Gullstrand, ni à leurs dérivés, ni encore aux ophtalmoscopes dont l’usage est principalement destiné à la saisie et/ou au traitement des images telles que celles obtenues avec les techniques de balayage laser.</span></p>
Reģistrācijas numurs (WIID) 83736
Darbības sfēra <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="FR" style="mso-bidi-font-size: 12.0pt;">Le présent document, conjointement avec les <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">ISO</span></span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">15004</span></span></span>‑<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">1</span></span></span> et <span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">ISO</span></span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">15004</span></span></span>‑<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">2</span></span></span>, spécifie les exigences minimales et les méthodes d’essai relatives aux ophtalmoscopes indirects à maniement manuel, de type binoculaire porté sur la tête, conçus pour l’observation indirecte des images du fond de l’œil.</span></p>
<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="FR" style="mso-bidi-font-size: 12.0pt;">Le présent document a la priorité sur l’<span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">ISO</span></span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">15004</span></span></span>‑<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">1</span></span></span> et l’<span class="stdpublisher"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">ISO</span></span></span> <span class="stddocNumber"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">15004</span></span></span>‑<span class="stddocPartNumber"><span style="color: black; mso-color-alt: windowtext; border: none;"><span style="border: none;">2</span></span></span> lorsque des différences existent.</span></p>
<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="FR" style="mso-bidi-font-size: 12.0pt;">Il ne s’applique pas aux lentilles convergentes utilisées en ophtalmoscopie indirecte, ni aux accessoires.</span></p>
<p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="FR" style="mso-bidi-font-size: 12.0pt;">Le présent document ne s’applique pas aux instruments montés sur table tels que les ophtalmoscopes de Gullstrand, ni à leurs dérivés, ni encore aux ophtalmoscopes dont l’usage est principalement destiné à la saisie et/ou au traitement des images telles que celles obtenues avec les techniques de balayage laser.</span></p>
Statuss Standarts spēkā
ICS grupa 11.040.70