This document specifies conformance tests for a system under test (SUT) implementing hydrogen vehicle
and hydrogen dispenser according to the generic fuelling communication requirements defined in ISO 19885
2 and the fueling-protocol specific communication requirements defined in ISO 19885-3.
The test system will comprise:
- a hydrogen vehicle tester to verify the communication behaviour of a hydrogen vehicle SUT; - a hydrogen dispenser tester to verify the communication behaviour of a hydrogen dispenser SUT; - a public key infrastructure (PKI) and other secondary actors to verify the security behaviour of a hydrogen
vehicle SUT and a hydrogen dispenser SUT; and - a fueling control system, implementing a fueling protocol, to verify the communication behaviour of a
hydrogen vehicle SUT and a hydrogen dispenser SUT under the control of a fueling protocol
This document specifies test cases for the requirements defined in ISO 19885-2 and the fueling-protocol
specific communication protocol requirements defined in ISO 19885-3, covering the following aspects: - use cases other than those performed by physical or data-link layer of fueling communication or pairing
communication; - fueling-protocol-specific requirements of each fueling protocol; and - interaction of the communication module with underlying fueling system or fueling protocol
The test cases will focus on black-box testing of the communication module of a hydrogen vehicle or
dispenser, while relevant secondary actors, such as PKI or fuelling system, are under the control of the test
system to ensure reproduceable test results.
Reģistrācijas numurs (WIID)
95382
Darbības sfēra
This document specifies conformance tests for a system under test (SUT) implementing hydrogen vehicle
and hydrogen dispenser according to the generic fuelling communication requirements defined in ISO 19885
2 and the fueling-protocol specific communication requirements defined in ISO 19885-3.
The test system will comprise:
- a hydrogen vehicle tester to verify the communication behaviour of a hydrogen vehicle SUT; - a hydrogen dispenser tester to verify the communication behaviour of a hydrogen dispenser SUT; - a public key infrastructure (PKI) and other secondary actors to verify the security behaviour of a hydrogen
vehicle SUT and a hydrogen dispenser SUT; and - a fueling control system, implementing a fueling protocol, to verify the communication behaviour of a
hydrogen vehicle SUT and a hydrogen dispenser SUT under the control of a fueling protocol
This document specifies test cases for the requirements defined in ISO 19885-2 and the fueling-protocol
specific communication protocol requirements defined in ISO 19885-3, covering the following aspects: - use cases other than those performed by physical or data-link layer of fueling communication or pairing
communication; - fueling-protocol-specific requirements of each fueling protocol; and - interaction of the communication module with underlying fueling system or fueling protocol
The test cases will focus on black-box testing of the communication module of a hydrogen vehicle or
dispenser, while relevant secondary actors, such as PKI or fuelling system, are under the control of the test
system to ensure reproduceable test results.