ISO/TC 204
Projekta Nr. | ISO/TS 37444:2023 |
---|---|
Nosaukums | <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document defines the charging performance metrics to be used during the evaluation or on-going monitoring of an electronic fee collection (EFC) system and the examination framework for the measurement of these metrics.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">It specifies a method for the specification and documentation of a specific examination framework which can be used by the responsible entity to evaluate charging performance for a particular information exchange interface or for overall charging performance within a toll scheme.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">The following scheme types are within the scope of this document:</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">a)<span style="mso-tab-count: 1;"> </span>discrete schemes;</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">b)<span style="mso-tab-count: 1;"> </span>continuous schemes (autonomous type of systems).</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document defines measurements only on standardized interfaces.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document defines metrics for the charging performance of EFC systems in terms of the level of errors associated with charging computation.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document describes a set of metrics with definitions, principles and formulations, which together make up a reference framework for the establishment of requirements for EFC systems and the subsequent examination of charging performance.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document defines metrics for the following information exchanges:</span></p> <p class="ListContinue1" style="margin-left: 17.85pt; text-indent: -17.85pt; tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>charge reports (including usage evidence);</span></p> <p class="ListContinue1" style="margin-left: 17.85pt; text-indent: -17.85pt; tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>toll declarations;</span></p> <p class="ListContinue1" style="margin-left: 17.85pt; text-indent: -17.85pt; tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>exception lists;</span></p> <p class="ListContinue1" style="margin-left: 17.85pt; text-indent: -17.85pt; tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>billing details and associated event data;</span></p> <p class="ListContinue1" style="margin-left: 17.85pt; text-indent: -17.85pt; tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>payment claims on the level of service user accounts;</span></p> <p class="ListContinue1" style="margin-left: 17.85pt; text-indent: -17.85pt; tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>end-to-end metrics which assess the overall performance of the charging process.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">These metrics focus solely on the outcome of the charging process, i.e. the amount charged in relation to a pre-measured or theoretically correct amount, rather than intermediate variables from various components as sensors, such as positioning accuracy, signal range or optical resolution. This approach ensures comparable results for each metric in all relevant situations.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">The following aspects are outside the scope of this document.</span></p> <p class="ListContinue1" style="margin-left: 17.85pt; text-indent: -17.85pt; tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>Definition of specific numeric performance bounds, or average or worst-case error bounds in percentage or monetary units.</span></p> <p class="ListContinue1" style="margin-left: 17.85pt; text-indent: -17.85pt; tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>Specification of a common reference system which would be required for comparison of performance between systems.</span></p> <p class="ListContinue1" style="margin-left: 17.85pt; text-indent: -17.85pt; tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>Measurements on proprietary interfaces. </span></p> <p class="Noteindent"><span lang="EN-GB">NOTE<span style="mso-tab-count: 1;"> </span>It is not possible to define standardized metrics on such system properties. Neither is it possible to define metrics for parts of the charging processing chain which are considered to be the internal matter of an interoperability partner, such as:</span></p> <p class="Noteindentcontinued"><span lang="EN-GB">—<span style="mso-tab-count: 1;"> </span>equipment performance, e.g. for on-board equipment (OBE), roadside equipment (RSE) or data centres such as signal range, optical resolution or computing system availability;</span></p> <p class="Noteindentcontinued"><span lang="EN-GB">—<span style="mso-tab-count: 1;"> </span>position performance metrics: the quality of data generated by position sensors is considered as an internal aspect of the GNSS front end. It is masked by correction algorithms, filtering, inferring of data and the robustness of the charge object recognition algorithms.</span></p> <p class="ListContinue1" style="margin-left: 17.85pt; text-indent: -17.85pt; tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>The evaluation of the expected performance of a system based on modelling and measured data from a trial at another place.</span></p> |
Reģistrācijas numurs (WIID) | 82970 |
Darbības sfēra | <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document defines the charging performance metrics to be used during the evaluation or on-going monitoring of an electronic fee collection (EFC) system and the examination framework for the measurement of these metrics.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">It specifies a method for the specification and documentation of a specific examination framework which can be used by the responsible entity to evaluate charging performance for a particular information exchange interface or for overall charging performance within a toll scheme.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">The following scheme types are within the scope of this document:</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">a)<span style="mso-tab-count: 1;"> </span>discrete schemes;</span></p> <p class="ListNumber1" style="tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">b)<span style="mso-tab-count: 1;"> </span>continuous schemes (autonomous type of systems).</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document defines measurements only on standardized interfaces.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document defines metrics for the charging performance of EFC systems in terms of the level of errors associated with charging computation.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document describes a set of metrics with definitions, principles and formulations, which together make up a reference framework for the establishment of requirements for EFC systems and the subsequent examination of charging performance.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">This document defines metrics for the following information exchanges:</span></p> <p class="ListContinue1" style="margin-left: 17.85pt; text-indent: -17.85pt; tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>charge reports (including usage evidence);</span></p> <p class="ListContinue1" style="margin-left: 17.85pt; text-indent: -17.85pt; tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>toll declarations;</span></p> <p class="ListContinue1" style="margin-left: 17.85pt; text-indent: -17.85pt; tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>exception lists;</span></p> <p class="ListContinue1" style="margin-left: 17.85pt; text-indent: -17.85pt; tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>billing details and associated event data;</span></p> <p class="ListContinue1" style="margin-left: 17.85pt; text-indent: -17.85pt; tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>payment claims on the level of service user accounts;</span></p> <p class="ListContinue1" style="margin-left: 17.85pt; text-indent: -17.85pt; tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>end-to-end metrics which assess the overall performance of the charging process.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">These metrics focus solely on the outcome of the charging process, i.e. the amount charged in relation to a pre-measured or theoretically correct amount, rather than intermediate variables from various components as sensors, such as positioning accuracy, signal range or optical resolution. This approach ensures comparable results for each metric in all relevant situations.</span></p> <p class="MsoBodyText" style="mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">The following aspects are outside the scope of this document.</span></p> <p class="ListContinue1" style="margin-left: 17.85pt; text-indent: -17.85pt; tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>Definition of specific numeric performance bounds, or average or worst-case error bounds in percentage or monetary units.</span></p> <p class="ListContinue1" style="margin-left: 17.85pt; text-indent: -17.85pt; tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>Specification of a common reference system which would be required for comparison of performance between systems.</span></p> <p class="ListContinue1" style="margin-left: 17.85pt; text-indent: -17.85pt; tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>Measurements on proprietary interfaces. </span></p> <p class="Noteindent"><span lang="EN-GB">NOTE<span style="mso-tab-count: 1;"> </span>It is not possible to define standardized metrics on such system properties. Neither is it possible to define metrics for parts of the charging processing chain which are considered to be the internal matter of an interoperability partner, such as:</span></p> <p class="Noteindentcontinued"><span lang="EN-GB">—<span style="mso-tab-count: 1;"> </span>equipment performance, e.g. for on-board equipment (OBE), roadside equipment (RSE) or data centres such as signal range, optical resolution or computing system availability;</span></p> <p class="Noteindentcontinued"><span lang="EN-GB">—<span style="mso-tab-count: 1;"> </span>position performance metrics: the quality of data generated by position sensors is considered as an internal aspect of the GNSS front end. It is masked by correction algorithms, filtering, inferring of data and the robustness of the charge object recognition algorithms.</span></p> <p class="ListContinue1" style="margin-left: 17.85pt; text-indent: -17.85pt; tab-stops: 19.85pt 39.7pt 59.55pt 79.4pt 99.25pt 119.05pt 138.9pt 158.75pt 178.6pt 7.0cm; mso-layout-grid-align: none; text-autospace: none;"><span lang="EN-GB" style="mso-bidi-font-size: 12.0pt;">—<span style="mso-tab-count: 1;"> </span>The evaluation of the expected performance of a system based on modelling and measured data from a trial at another place.</span></p> |
Statuss | Standarts spēkā |
ICS grupa | 03.220.20 35.240.60 |