<p>ISO 19628:2017 describes two methods for the determination of the specific heat capacity of ceramic matrix composites with continuous reinforcements (1D, 2D, 3D).</p>
<p>Unidirectional (1D), bi-directional (2D) and tridirectional (XD, with 2 < x ≤ 3).</p>
<p>The two methods are:</p>
<p>- method A: drop calorimetry;</p>
<p>- method B: differential scanning calorimetry.</p>
<p>They are applicable from ambient temperature up to a maximum temperature, depending on the method: method A can be used up to 2 250 K, while method B is limited to 1 900 K.</p>
<p>NOTE Method A is limited to the determination of an average value of the specific heat capacity over a given temperature range and can give a larger spread of results.</p>
Reģistrācijas numurs (WIID)
65569
Darbības sfēra
<p>ISO 19628:2017 describes two methods for the determination of the specific heat capacity of ceramic matrix composites with continuous reinforcements (1D, 2D, 3D).</p>
<p>Unidirectional (1D), bi-directional (2D) and tridirectional (XD, with 2 < x ≤ 3).</p>
<p>The two methods are:</p>
<p>- method A: drop calorimetry;</p>
<p>- method B: differential scanning calorimetry.</p>
<p>They are applicable from ambient temperature up to a maximum temperature, depending on the method: method A can be used up to 2 250 K, while method B is limited to 1 900 K.</p>
<p>NOTE Method A is limited to the determination of an average value of the specific heat capacity over a given temperature range and can give a larger spread of results.</p>