| Nosaukums | <p class="MsoBodyText"><span lang="EN-GB">This document specifies safety requirements and protective/risk reduction measures, and the means for their verification, for all types and sizes of mobile elevating work platforms (MEWPs) intended for moving a person(s) along with their necessary tools and materials at an elevated work location.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document also applies to MEWPs designed for applications requiring special access to specific work areas. These MEWPs can be either self-propelled or manually propelled and are used to elevate personnel to a level at which they can place, install, or retrieve objects or material on a routine basis. To facilitate operator access to the work area, the retraction of a portion of the MEWP's work platform guardrail system(s) can be necessary.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document is intended to serve as a guide for manufacturers and remanufacturers of MEWPs to achieve the following objectives:</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">elimination or reduction of accidents and personal injuries;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">establishment of criteria for design, manufacture, remanufacture, rebuild/recondition, testing and performance;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">establishment and understanding by manufacturers and remanufacturers of their responsibilities.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">The design and manufacturing requirements of this document apply to all MEWPs manufactured or remanufactured on or after the effective date, but it is not applicable to rebuilt or reconditioned MEWPs.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">It identifies the hazards arising from the use of MEWPs and describes methods for the elimination or reduction of these hazards.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document is not applicable to</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">a)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">permanently installed personnel-lifting appliances serving defined levels,</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">b)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">firefighting and fire rescue appliances (see for example, EN 1777),</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">c)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">unguided work cages suspended from lifting appliances (see for example, EN 1808),</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">d)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">elevating operator position on rail-dependent storage and retrieval equipment (see for example, EN 528),</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">e)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">tail lifts (see for example, EN 1756-1:2001+A1:2008, EN 1756-2:2004+A1:2009),</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">f)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">mast-climbing work platforms (see ISO 16369),</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">g)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">fairground equipment,</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">h)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">lifting tables with a lifting height of less than 2 m (see for example, EN 1570-1:2011+A1:2014),</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">i)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">builder's hoists for persons and materials,</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">j)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">aircraft ground-support equipment (see for example, EN-1915-1:2013, EN-1915-2:2001+A1:2009),</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">k)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">digger derricks,</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">l)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">elevating operator positions on industrial trucks (see for example, ISO 3691-3),</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">m)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">elevating operator positions on cranes,</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">n)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">certain requirements for insulating aerial devices on a chassis for use in live work on electrical installations (see Note 1),</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">o)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">multi-purpose elevating platform powered industrial trucks (MPEPs) controlled by a single stand-up riding operator and intended to be used for manually picking and transporting small items at height,</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">p)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">powered industrial trucks used to pick and place stock or inventory.</span></p>
<p class="Note"><span lang="EN-GB">NOTE 1<span style="mso-tab-count: 1;"> </span>For requirements for use near live electrical installations, see ISO 16653-2. For requirements for use on live electrical installations, see IEC 61057.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">It does not cover hazards arising from:</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">use in potentially explosive atmospheres,</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">use of compressed gases for load-bearing components,</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">derailment and runaway of rail-mounted MEWPs,</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">work on live electrical systems (see Note 2 and Note 3).</span></p>
<p class="Note"><span lang="EN-GB">NOTE 2<span style="mso-tab-count: 1;"> </span>Hazards arising from work on live electrical systems are addressed in IEC 61057.</span></p>
<p class="Note"><span lang="EN-GB">NOTE 3<span style="mso-tab-count: 1;"> </span>For MEWPs that employ aerial devices used for live working, this document is to be used in conjunction with IEC 61057, taking into consideration the potential exceptions from this document that are specified in IEC 61057.</span></p> |
| Darbības sfēra | <p class="MsoBodyText"><span lang="EN-GB">This document specifies safety requirements and protective/risk reduction measures, and the means for their verification, for all types and sizes of mobile elevating work platforms (MEWPs) intended for moving a person(s) along with their necessary tools and materials at an elevated work location.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document also applies to MEWPs designed for applications requiring special access to specific work areas. These MEWPs can be either self-propelled or manually propelled and are used to elevate personnel to a level at which they can place, install, or retrieve objects or material on a routine basis. To facilitate operator access to the work area, the retraction of a portion of the MEWP's work platform guardrail system(s) can be necessary.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document is intended to serve as a guide for manufacturers and remanufacturers of MEWPs to achieve the following objectives:</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">elimination or reduction of accidents and personal injuries;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">establishment of criteria for design, manufacture, remanufacture, rebuild/recondition, testing and performance;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">establishment and understanding by manufacturers and remanufacturers of their responsibilities.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">The design and manufacturing requirements of this document apply to all MEWPs manufactured or remanufactured on or after the effective date, but it is not applicable to rebuilt or reconditioned MEWPs.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">It identifies the hazards arising from the use of MEWPs and describes methods for the elimination or reduction of these hazards.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document is not applicable to</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">a)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">permanently installed personnel-lifting appliances serving defined levels,</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">b)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">firefighting and fire rescue appliances (see for example, EN 1777),</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">c)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">unguided work cages suspended from lifting appliances (see for example, EN 1808),</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">d)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">elevating operator position on rail-dependent storage and retrieval equipment (see for example, EN 528),</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">e)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">tail lifts (see for example, EN 1756-1:2001+A1:2008, EN 1756-2:2004+A1:2009),</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">f)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">mast-climbing work platforms (see ISO 16369),</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">g)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">fairground equipment,</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">h)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">lifting tables with a lifting height of less than 2 m (see for example, EN 1570-1:2011+A1:2014),</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">i)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">builder's hoists for persons and materials,</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">j)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">aircraft ground-support equipment (see for example, EN-1915-1:2013, EN-1915-2:2001+A1:2009),</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">k)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">digger derricks,</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">l)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">elevating operator positions on industrial trucks (see for example, ISO 3691-3),</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">m)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">elevating operator positions on cranes,</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">n)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">certain requirements for insulating aerial devices on a chassis for use in live work on electrical installations (see Note 1),</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">o)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">multi-purpose elevating platform powered industrial trucks (MPEPs) controlled by a single stand-up riding operator and intended to be used for manually picking and transporting small items at height,</span></p>
<p class="ListNumber1" style="mso-list: l1 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">p)<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">powered industrial trucks used to pick and place stock or inventory.</span></p>
<p class="Note"><span lang="EN-GB">NOTE 1<span style="mso-tab-count: 1;"> </span>For requirements for use near live electrical installations, see ISO 16653-2. For requirements for use on live electrical installations, see IEC 61057.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">It does not cover hazards arising from:</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">use in potentially explosive atmospheres,</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">use of compressed gases for load-bearing components,</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">derailment and runaway of rail-mounted MEWPs,</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">work on live electrical systems (see Note 2 and Note 3).</span></p>
<p class="Note"><span lang="EN-GB">NOTE 2<span style="mso-tab-count: 1;"> </span>Hazards arising from work on live electrical systems are addressed in IEC 61057.</span></p>
<p class="Note"><span lang="EN-GB">NOTE 3<span style="mso-tab-count: 1;"> </span>For MEWPs that employ aerial devices used for live working, this document is to be used in conjunction with IEC 61057, taking into consideration the potential exceptions from this document that are specified in IEC 61057.</span></p> |